SECTION 6
Completing the Installation
1.
Use a sealant appropriate for contact with the building materials
present and for the temperature requirements of the installation to
prevent air leakage from unconditioned spaces is recommended. If
gaps between unit housing and ceiling are great, additional material
(backing rod, ceiling material) may be required.
NOTE: This fan is rated for direct insulation contact (Type IC) and it is
recommended that this fan be completely covered by insulation in order to
reduce heat loss or gain to unconditioned space.
2.
Reinstall the fan's wire compartment cover. Rotate the blower wheel
by hand to ensure it spins freely. Plug the fan's quick connect motor
cord into the receptacle. This cord will only fit one way into the
receptacle (Figure 11).
Figure 11
NOTE: If using this fan to meet ASHRAE 62.2 requirements, locate the label
inside the fan housing and fill in the appropriate information.
3.
Install the grill by squeezing the two ends of the springs together and
installing them up into the slots of the fan's housing. Push the grill up
into position (Figure 12).
Trouble
1. Fan does not operate when the switch is on.
2. Fan is operating, but air moves slower than normal.
3. Fan is operating louder than normal
210572021 Rev. N 6-15
4.
SECTION 7
Use and Care
CAUTION:
PANEL BEFORE SERVICING THE UNIT.
1.
2.

Troubleshooting Guide

Probable Cause
1a.
A fuse may be blown or a circuit tripped.
1b.
Connector plug from motor is not plugged in. 1b.
1c.
Wiring is not connected properly.
1d
Motor has stopped operating.
2.
Obstruction in the exhaust ducting.
3a.
Motor is loose.
3b.
Fan blade is hitting housing of unit.
www.airkinglimited.com
Figure 12
Restore power and test your installation.
MAKE SURE POWER IS SWITCHED OFF AT SERVICE
Cleaning the Grill: Remove grill and use a mild detergent, such
as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY
ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill
before reinstalling. Refer to instructions in Section 6 Finishing the
Installation, to reinstall grill.
Cleaning the Fan Assembly: Unplug the motor cord from receptacle.
Wipe all parts with a dry cloth or gently vacuum the fan. NEVER
IMMERSE ELECTRICAL PARTS IN WATER. Plug the motor cord back in
and restore power.
Suggested Remedy
1a.
Replace fuse or reset circuit breaker.
Turn off power to unit. Remove Grill and plug motor into receptacle
in housing. Restore power to unit.
1c.
Turn off power to unit. Check that all wires are connected.
1d.
Replace motor.
2.
Check for any obstructions in the ducting. The most common are bird
nests in the roof cap or wall cap where the fan exhausts to the outside.
3a.
Turn off power to unit. Remove grill and check that all screws are fully
tightened. Restore power to unit.
3b.
Call your dealer for service.
4 of 12