6.2.1. MODEL ENCLOSED IN A CASE
MOUNTING IN THE CASE
Select the inlet axis of the gas according to
the specifi cations of the case;
Fix the base by means of the clamp with the
screws HM5 in the groove at the bottom of
the case (if necessary, mount the spacers to
EN
compensate for the depth of the case).
SOLDERING THE PIPING :
The base being equipped with a tube
8×10 mm, it is possible to solder the socket on the piping without
disassembling the base valve;
It is important to protect the valve by surrounding the copper tubes and
the base with a damp cloth during the soldering operation.
MOUNTING THE COVER ASSEMBLY :
Fix the chromium-plated cover assembly on the front face of the case;
Fix the assembly by screwing the brass tightening nut onto the base of
the socket with the multifunction key;
Tighten to a moderate degree.
MOUNTING OF THE SOCKET HEAD :
Unscrew the valve-fi lter unit before fastening the socket head;
Fix the socket head in position by screwing the chromium-plated nut
onto the base using the multifunction key; (manual tightening of + ¼ turn
[sic] with the key).
Re-fasten the valve-fi lter unit;
Position the reception cap.
6.2.2. MODEL ENCLOSED IN A WALL
SEALING THE REAR FIXING PLATE :
Seal the rear plate after having embedded
the plastic housing, with the front face of
the housing being positioned with respect
to the surface of the wall ;
When the plaster has set, withdraw with
plastic housing.
MOUNTING
SOCKET:
Check that the base contains no sealing
gasket;
Solder the inlet pipe for the gas in the sleeve;
Fix the base on the rear plate, by the clamp using the 2 selftapping
screws;
Remount the plastic housing after having punched through the opening
intended for the passage of the supply pipe;
Fill in the space remaining outside the plastic housing with plaster.
:
OF
THE
BASE
OF
THE
6/40