2.1

Technical menu

In the technical menu you can view the integrated temperature and relative humidity (RH) measurements. In this
menu you can also reset the alarm and change the setpoint of the air flow sensor (SHC80). This menu can be
accessed by holding down the mode button for 2 sec.
Main menu
Submenu
SETPNT
SP01
SP02
TEMP
TS01
TS02
TS03
TS04
TS05
TS06
TS07
TS 08
HUM
RH01
RH02
COUNTR
CT01
CT02
ALARM
AL01
AL02
Menu navigation
1. Use the arrow buttons to change to the main menu
2. Press mode to select the menu
3. Use the arrow buttons to scroll between the submenus
4. Press mode to select a submenu
5. Use the arrow buttons to change the values
6. Press mode to confirm the change
7. Press
Section 2 – Controller menu
Description
Setpoint temperature in the duct
Setpoint RH duct
Measured duct temperature
Measured temperature after HRV
Measured outside temperature T3
Setpoint temperature humidifier
Setpoint temperature indirect cooler
Setpoint temperature direct cooler
Minimal supply-air temperature
Measured temperature return duct
Measured humidity in duct after
Evap
Measured humidity in return duct
Count valve humidifier
Count valve cooler
Turn off service alarm
Turn off alarm
to go back one step
Evap controller
Measured with the T1 sensor (SHC080)
Measured with the T2 sensor
If not connected, then standard 50
Standard set on 12
°C
Not applicable for the Brink Evap
Not applicable for the Brink Evap
Not applicable for the Brink Evap
Not applicable for the Brink Evap
Not applicable for the Brink Evap
°C