8. Starting up
GB
Important.
To prevent all danger, the machine must only
be held using the two handles (6/8). Otherwise
there may be a risk of suffering an electric shock if
you drill into cables.
8.1 Switching on and off (Fig. 1)
To switch on:
Press the control switch (4).
To switch off:
Release the control switch (4).
8.2 Hammer stop facility (Fig. 7)
The hammer drill has a hammer stop facility for
gentle initial drilling.
• Turn the rotary switch for the hammer stop
facility (5) to position (B) to switch off the
hammer facility.
• To switch on the hammer facility again the
rotary switch for the hammer stop facility (5) must
be turned back to position (A).
8.3 Rotation stop facility (Fig. 8 / 9)
The rotation function of the hammer drill can be
switched off for chiseling jobs.
• To do this, turn the rotary switch (3) into position
A (see Fig. 8).
• To switch on rotation facility again, turn the
rotary switch (3) into position B (see Fig. 9).
Important.
Please note that it is not possible to operate the
hammer drill with the hammer stop and rotation
stop facilities both active at the same time.
All manuals and user guides at all-guides.com
Important.
Only low pressure is required for hammer drilling.
Excessive pressure will exert an unnecessary force
on the motor. Check the drill bits at regular
intervals. Sharpen or replace blunt drill bits.

9. Replacing the power cable

If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
aftersales service or similarly trained personnel to
avoid danger.

10. Technical data

Mains voltage:
Power input:
Idling speed:
Blow rate:
Drilling capacity in concrete/stone (max.): 32 mm
Protection class:
Weight:
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L
: sound pressure level
pA
K
: uncertainty
pA
L
: sound power level
WA
K
: uncertainty
WA
The hammer drill is not designed for outdoors
use as specified I Article 3 of Directive 2000/14/
EC_2005/88/EC.
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Total vibration values (vector sum of three
directions) determined in accordance with EN
60745.
16
230 V~/ 50 Hz
1500 W
0-800 rpm
0-4500 rpm
II /
5.3 kg
95 dB(A)
3 dB(A)
106 dB(A)
3 dB(A)