User Guide Fleck 5800-XTR
3 .
Description
3.1.
Technical specifications
Pressure: ..........................................................Hydrostatic: 20 bar; Working: 1.4 - 8.6 bar
Maximum service flow rate (ΔP 1.7 bar): .........6.1 m
3.2.

Environmental conditions

• Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C;
• main supply voltage fluctuations up to ±10% of the nominal voltage;
• temperature from 0 °C to 52 °C;
• not directly exposed to the sun;
• installed in a dry place.
3.3.
Description and components location
3.4.
By-passing
If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture
below.

Normal operation

In
6 / 52
3
/h
Brine
Drain
Mixing device
Outlet
Meter
Inlet
Softening System
Out
Display
In Bypass
Softening System
In
Ref. MKT-UG-006 / C - 18.09.2019
Out