Condition Monitoring - FLIR A400 Serie Guide De Démarrage Rapide

Table des Matières

Publicité

3 EN-US English
7.
In the web interface and on the tab Move camera, use the arrow buttons to
control the P/T device.
3.9 Example system overviews
3.9.1 Early fire detection
Hot spot detection, self-combustible material on conveyor belt, see Figure 2.5
Example system overview: early fire detection, page 3.
1.
Coal mine conveyor belt.
2.
FLIR A400/A700 Smart Sensor camera.
3.
Ethernet connector, X-coded.
4.
Power I/O connector, A-coded.
5.
Digital output to a programmable logic controller (PLC).
6.
Separate DIN rail power supply for galvanic isolation (18–56 V DC).
7.
Laptop used for set up of the camera using the web interface.
8.
Ethernet switch.
9.
MQTT output connected to a third-party cloud service.
10. Example thermal mage.

3.9.2 Condition monitoring

24/7 Monitoring of critical assets, see Figure 2.6 Example system overview: con-
dition monitoring, page 4.
1.
Computer running custom-made software.
2.
CAT 6 Ethernet cable.
3.
Industrial power over Ethernet (PoE) switch.
4.
FLIR A400/A700 Image Streaming cameras.
5.
Industrial process to be monitored, e.g., a gasifier.
6.
Example thermal image.
3.9.3 Research and development
Checking heat dissipation on a PCB during development, see Figure 2.7 Exam-
ple system overview: research and development, page 4.
1.
Computer running FLIR science software, e.g., FLIR Research Studio.
2.
CAT 6 Ethernet cable.
3.
Laboratory setup with a FLIR A400/A700 Image Streaming camera.
4.
Example thermal image.
#T810482; r. AA/64581/64581; mul
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

A700 serie

Table des Matières