12.1 Adding Oil to the Pump
Warning: Always add oil with cylinders fully
retracted (extended if pull cylinders) or the
system will contain more oil than the reservoir
can hold.
-
Remove vent/fill cap from reservoir,
-
Only fill the oil to approx. 2.0-2.5 cm below the upper
edge of the oil container (depending on the size of the
container),
-
Remove air from system if necessary. See 8.3. Recheck oil
level after removing air,
-
Return vent/fill cap to proper position.
-
Make sure no dirt gets into the oil reservoir or into the
pump, as this will cause malfunction.
-
To extend pump life and improve performance, lubricate
the beam pin, cross pin and piston head regulary, using
roller bearing grease.
13.
Transport
13.1 For transport, the lever and the bolting device has to be a
locking position. The lever can be used as a carrying handle.
14.
Troubleshooting
Cylinder does
Oil level in pump
not advance,
reservoir is low
advances
slowly, or
Drain valve open
advances in
spurts
Loose hydraulic
coupler
Load is too heavy
Air trapped in system
Cylinder plunger
binding
Cylinder
Leaking connection
advances, but
does not hold
Leaking seals
pressure
Internal leakage in
pump
Add oil according to the
Maintenance instructions
on 12.1
Drain valve closed
Check that all couplers are
fully tightened
Do not attempt to lift more
than rated tonnage
Remove air according to the
instructions on page 8.3
Check for damage to
cylinder; have cylinder
by a authorised dealer or
Weitner themselves
Check that all connections
are tight and leak free
Locate leak(s) and have
equipment serviced by
authorised dealer or
Weitner themselves
Have pump serviced by
a authorised dealer or
Weitner themselves
Cylinder does
Drain valve closed
not retract,
retracts part
way, or
retracts more
slowly than
normal
Cylinder does
Pump reservoir is
not retract,
over-filled
retracts part
way, or
Loose hydraulic
retracts more
coupler
slowly than
normal
Air trapped in system
Cylinder does
Hose I.D. too narrow
not retract,
retracts part
Cylinder retraction
way, or
spring brocken
retracts more
or other cylinder
slowly than
damage
normal
If the defects cannot be repaired, contact an authorised dealer or
the service department.
15.
Warranty conditions
15.1 Please refer to the general terms and conditions of the
manufacturer.
2.
Technical data
Type
Order no.
Operating pressure (psi)
Oil capacity / usable oil
capacity (l)
Oil delevery HP cm³
Dimensions LxBxH (mm)
Weight with oil (kg)
Open drain valve
Drain oil level to full mark.
See 12.1 instructions for
adding oil
Check that all couplers are
fully tightened
Remove air according to the
instructions 8.3
Use larger diameter
hydraulic hose
Have cylinder serviced
by a authorised dealer or
Weitner themselves
1952 004 001
1952 004 001 / Operating pressure
+ 58
5800 - 10150
- 14,5
0,5 / 0,7
2,0 per piston stroke
340 x 100 x 150
3,5
15