The customer's connection to the power supply system,
and any extension cables that may be used, must con-
form with local regulations.
Defective electrical connection cables
Electrical connection cables offen suffer insulation dar-
nage.
Possible causes are:
• Punch points when connection cables are run through
window or door gaps.
• Kinks resulting from incorrect attachment or laying of
the connection cable.
• Cuts resulting from running over the connecting ca-
ble.
• Insulation darnage resulting from forcefully pulling out
of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables must not be
used as the insulation darnage makes them extremely haz-
ardous.
Check electrical connection cables regularly for darnage.
Make sure the cable is disconnected from the mains
when checking.
Electrical connection cables must comply with the regu-
lations applicable in your country .
Single-phase motor
• The mains voltage must coincide with the voltage spec-
ified on the motor.s rating plate.
• Dimension cables up to a length of 25 m must have a
cross-section of 1.5 mmª. and beyond 25 m at least
2.5 mmª.
• The connection to the mains must be protected with a
16 A slowacting fuse.
Important remark:
The motor is automatical/y switched off in the event of
an overload. The motor can be switched on again after a
cooling down period that can vary.
Three-phase motor
• The mains voltage must be between 380 and 420 V
/ 50 Hz.
• The connection to the mains and the connection cable
must have five leads (3 P + N + PE).
• Extension cables must have a cross-section of at least
1.5 mm2.
Warning:
The drill press must not be operated in the open air. The
machine must have an earth Gable to protect the operator
from etectrical shocks.