Télécharger Imprimer la page

Caractéristiques Techniques; List Of Controls - VOLTCRAFT VSP Série Notice D'emploi

Masquer les pouces Voir aussi pour VSP Série:

Publicité

Caractéristiques techniques
Nº de commande
511903
No du modèle
VSP 1220 HE
Tension d'opération
Fréquence de puissance
Consommation du courant (max.)
max. 500VA
Puissance délivrée
409W
0.1-20V
Tension de sortie (DC), Sortie A
réglage continu
0.1-6V
Tension de sortie (DC), Sortie B
réglage continu
0.1-20A
Courant de sortie (DC), Sortie A
réglage continu
Courant de sortie (DC), Sortie B
Fusible F1
T3.15A
a) 0.025% de Vmax.
Fluctuation sous charge normale
b) 0.005% de Vmax.
Résistance de la tension (U) un
< 0.13% de Vmax
balancement de charge de 100%
Résistance de la tension avec
un changement de tension de
< 0.005% de Vmax
±20%AC
Résistance du courant (I) avec un
< 5mA
balancement de charge de 100%
Résistance du courant avec
un changement de tension de
< 5mA
±20%AC
Température fonctionnement
Humidité relative
Classe de protection
Poids (approx.)
Dimensions (L x W x H, en mm)
24
511901
511906
VSP 1410 HE
VSP 1605 HE
230 V~ AC +/-20%
47-53 Hz
max. 500VA
max. 500VA
409W
334W
0.1-40V
0.1-65V
réglage continu
réglage continu
0.1-6V
0.1-6V
réglage continu
réglage continu
0.1-10A
0.1-5A
réglage continu
réglage continu
1.5A
1.5A
T3.15A
T3.15A
a) 0.0125% de Vmax.
a) 0.0125% de Vmax.
b) 0.005% de Vmax.
b) 0.005% de Vmax.
< 0.03% de Vmax
< 0.03% de Vmax
< 0.0025% de Vmax
< 0.0025% de Vmax
< 6mA
< 5mA
< 6mA
< 5mA
de 0 à 40°C
approx. 80%, sans condensation
1
5.8 kg
333 x 340 x 88
Do not wear metallic or conductive jewellery such as chains, bracelets, rings, etc. when operating the device.
The device must not be used on human beings or animals.
The device shall not be subjected to heavy mechanical stress.
The device must not be exposed to extreme temperatures, direct sunlight, intense vibration or moisture.
Position the device on a level and sturdy surface.
The device generates operational heat. Never insert any objects, block cooler opening of the device, or hinder ventilation in
any form or manner. The device is predominantly cooled by convection.
Never put a naked flame or any containers with liquids on or near the apparatus.
Caution! Capacitors within the device may retain their charge even if the device is disconnected from all power sources.
Never turn on the device immediately after it has been brought from a cool into a warmer environment. Condensing water
might destroy your device. Leave the device in OFF position and wait until it has reached ambient temperature.
Before operating the device, make sure that your hands, shoes, clothing, the floor as well as the device itself are dry.
During thunderstorm, unplug the device's power plug from the mains outlet in order to avoid damages due to excess
voltage.
In industrial facilities, the safety regulations laid down by the professional trade association for electrical equipment and
facilities must be observed.
In schools, training facilities, DIY and hobby workshops, the usage of electrical devices is to be supervised by trained
personnel.
If there is reason to believe that safe operation is no longer possible, the device is to be put out of operation and secured
against unintended operation. Safe operation is no longer possible if:
-the device has sustained visible damages,
-the device no longer works,
-and the device was stored under unfavourable conditions for a long period of time,
-the device was subject to considerable transport stress.
This device is not a toy and should be kept out of reach of children!
Servicing, adjustment, or repair works must only be carried out by a specialist/specialist workshop.
Should you have any questions that are not answered in this operating manual, please contact our technical customer
service, or other experts.

List of Controls

Please refer to drawings on the fold out on page 3.
(a) = Output A "A-OUTPUT"
(b) = Output B "B-OUTPUT"
Front side
LED power status indicator (lit in red when power supply is ON)
(1)
(2)
Power switch (I = ON / 0 = OFF)
(3)
Safety connection sockets for power output DC (red = +, blue = -)
Display Current and Voltage („A" = output current and „V" = output voltage)
(4)
(5)
Turn controls "V" (sets output voltage „Coarse" and „Fine")
(6)
Turn controls "A" (sets current limiting „Coarse" and „Fine")
CV-LED (green LED "CV" indicates the active voltage)
(7)
(8)
CC-LED (red LED "CC" indicates the current limit)
(9)
Over-temperature ("OT" indicates overheating of the device)
Connection socket for earth wire of loads (yellow/green)
(10)
(11)
Pushbutton for display switching „show value"
(12)
Turn control „V-adjust" (Setting output voltage)
Overload-LED (indicates overload on respective output)
(13)
Rear side
Terminal strip (for external programming and remote sensing)
(14)
(15)
Cold device connector
(16)
Fuse holder of mains fuse
13

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

Vsp 1220 heVsp 1410 heVsp 1605 he