Campbell Scientific Sonic SR50A Manuel D'utilisation page 48

Table des Matières

Publicité

Capteur de télémétrie sonique SR50A
4: 3
Loc [ SR50ATDIS ]
5: 1.0
Multiplier
6: 0.0
Offset
;Set the initial distance from the SR50A to the ground in meters:
2: Z=F x 10^n (P30)
1: 2.5
F
2: 00
n, Exponent of 10
3: 2
Z Loc [ DisToGnd ]
;Subtract the Distance to the snow surface from the Distance to Ground
;to obtain snow depth
3: Z=X-Y (P35)
1: 2
Z Loc [ DisToGnd ]
2: 3
Y Loc [ SR50ATDIS ]
3: 6
Z Loc [ SnowDepth ]
;Hourly Data Output
4: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
5: Set Active Storage Area (P80)
1: 1
Final Storage Area 1
2: 60
Array ID
6: Real Time (P77)
1: 1220
Year,Day,Hour/Minute (midnight = 2400)
7: Sample (P70)
1: 1
Reps
2: 6
Loc [ SnowDepth ]
;Store the Signal quality value
8: Sample (P70)
1: 1
Reps
2: 4
Loc [ Sig_Qual ]
;Store the Temperature reading from the SR50AT
9: Sample (P70)
1: 1
Reps
2: 5
Loc [ SR50AT_T ]
*Table 2 Program
02: 0.0000
Execution Interval (seconds)
*Table 3 Subroutines
End Program
- 46 -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sonic sr50at

Table des Matières