Installation Notes
LPS350-CEF Series
Input Specifications
Input range
85 VAC to 264VAC
120 VDC to 370 VDC
Frequency
47 - 440 Hz
Inrush current
<38 A peak
75% typical at full load
Efficiency
Power factor
0.99 typical,
meets EN61000-3-2
EMI filter
Meets FCC Class B
CISPR 22 Class B
(includes EN55022 class B and
VDE 0878 PT3 class B)
Electromagnetic
Meets IEC801-2 level 3,
compatibility
and IEC801-5 level 3
Safety ground
< 0.5mA @50/60Hz, 264VAC
input
leakage current
Environmental
Operating temperature: 0°C to 50°C ambient;
derate at 2.5% / °C from 50°C to 70°C
Storage temperature:-40°C to 85°C
Thermal regulation: ± 0.04% / °C
MTBF:
> 100,000 hours at full load and 25°C
ambient conditions
Notes (refer to table)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output
voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF
capacitor.
4. Continuous maximum power drawn must not exceed 350W with fan cooling.
Mating Connectors
SK1 AC Input:
Screw terminals M3.5 spade
TB1 Main DC O/p: Screw terminals M3.5 spade
SK3 Auxiliary:
Housing Molex 22-01-1102
SK4,5,6 Aux, Fan: Housing Molex 22-01-1022
Crimps: 22/30 AWG Molex 08-50-0032
Notes
1 Specifications subject to change without notice.
2 All dimensions are in mm and (inches).
3 Output Common capacitivily coupled to chassis earth.
4 Fan supply inhibited when power supply inhibited. If
continuous fan operation required move plug from SK6 to
SK4.
5 Weight 1.9 kg / 4.2 lb.
Warning: Hazardous mains voltages present within
this unit. Please see enclosed 'Astec Installation and
Operating Instructions'.
350 Watts
IEC801-4 level 3
(or 22-01-2085)
(or 22-01-2025)
(or 08-50-0114)
Single Output
Output Specifications
350W
Maximum
wattage
2 : 1 voltage adjustment (output is fully adjust-
Adjustment
able between values quoted in model table via
range
trimmer)
Hold-up time
20 ms at 350W load and 115 VAC nominal line
Case overload protected10% to 35% above
Overload
400W.
protection
Short circuit protection on all outputs. Auto
Overcurrent
recovery. Constant current limit on each output
protection
5 to 50% above max rated output.
Overvoltage
10% to 25% above output voltage setting.
Recycle AC to reset.
protection
Supervisory
5V / 500mA regulated; output maintained when
main outputs inhibited. (for use with inhibit and
output
power good function)
12V / 500mA; SK4 output maintained when
Fan output
main outputs inhibited. SK6 output inhibited
when main outputs inhibited.(note 4)
Safety
VDE
UL
CSA
NEMKO
BABT
CB
This product is CE marked following
the provisions of the Low Voltage
Directive 73/23/EEC
Auxiliary Connections
1 Remote sense -Main output - optional connection-
can compensate for up to 0.5V drop; internal local
sense connected if not used. Protected against
reverse connection.
2 AC Power Fail signal;-TTL compatible signal goes
high 50-150ms after switch on. Goes low >4 ms
before 5V drops to 4.75V.
3 DC Power OK:- TTL compatible signal goes high
at same time as AC Power Fail. Goes low when 5V
drops to 4.75V.
4 Remote Inhibit. Connecting pin 8 to pin 10
(common) will inhibit the outputs.
5 Remote Enable. To convert to enable, cut jumper
J1; connecting pin 9 to pin 10 will enable outputs.
6 Paralleling power supplies - when the 'C share'
signal is connected between two power supplies
the main 5V outputs will current share.
Fusing
Input fuse 10A 20mm Quick Acting HBC
mains fuse - only replace with same type
and rating to maintain safety standards.
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 3
EN 60950/EMKO-TUE (74-sec) 203
EN60950/BS7002
Certificate and report

Publicité

loading

Sommaire des Matières pour ASTEC LPS350-CEF Serie

  • Page 1 5V outputs will current share. Fusing Warning: Hazardous mains voltages present within Input fuse 10A 20mm Quick Acting HBC this unit. Please see enclosed ‘Astec Installation and mains fuse - only replace with same type Operating Instructions’. and rating to maintain safety standards.
  • Page 2 AC Power Fail Current share Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.
  • Page 3 Fusible Attention: Tension secteur dangereuse sur cette alimentation. Veuillez consulter la notice d’installation Fusible d’entrée 10A 20mm rapide HBC à remplacer par le même type et la même valeur ASTEC et les instructions d’utilisation. pour maintenir les homologations de sécurité.
  • Page 4 AC Power Fail Current share Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.
  • Page 5 Bedienungs Anleitung LPS350-CEF Serie 350 Watt Einfach Ausgang Eingangs Spezifikationen Ausgangs Spezifikationen Maximale 85 VAC to 264 VAC 350W Eingangsbereich 120 VDC bis 370 VDC Ausgangsleistung 47 - 440 Hz Frequenz Einstellbereich < 38 A Spitze Einschaltstrom Haltezeit 20 ms bei 350W Last und 115 VAC...
  • Page 6 Ausgangsnull AC Power Fail Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.

Ce manuel est également adapté pour:

Lps352-cefLps353-cefLps354-cefLps355-cef