Installation Notes
LPS110 Series
Input Specifications
Input range
85 VAC to 264 VAC
120 to 370 VDC
Frequency
47 - 440 Hz
Inrush current
< 18 A peak @ 115 VAC
< 36 A peak @ 230 VAC
Input current
2.5 A max. (RMS) @ 115 VAC
Efficiency
70% typical at full load
EMI filter
Meets FCC Class B
CISPR 22 Class B
(includes EN55022 class B and
VDE 0878 PT3 class B)
Electromagnetic
Meets IEC801-2 level 3,
compatibility
and IEC801-5 level 3
Safety ground
< 0.5mA @ 50/60Hz,
leakage current
264Vac input
Environmental
Operating temperature: 0°C to 50°C ambient;
derate at 2.5% / °C from 50°C to 70°C
Storage temperature:-40°C to 85°C
Thermal regulation: ± 0.04% / °C
MTBF:
> 100,000 hours at full load and 25°C
ambient conditions
Notes (refer to table)
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor.
4. Total power drawn must not exceed 80W with convection cooling or 110W fan cooled.
Mating Connectors
AC Input:
Housing Molex 09-91-0500
DC Output:
Housing Molex 09-91-0900
Contacts:
18/24 AWG Molex 08-50-0106
Sense / P OK: Housing Molex 22-01-2025
Contacts:
22/30 AWG Molex 08-50-0114
Notes
1 Specifications subject to change without notice.
2 All dimensions are in mm and (inches).
3 Mounting holes M1 and M2 should be earthed for EMI purposes.
4 Output Common capacitivily coupled to M2 earth.
5 Mounting hole M1 is safety earth connection. This power supply
must be earthed for safe operation via mounting hole M1 or SK1-3
connector.
6 Weight 0.75 kg / 1.65 lb.
Warning: Hazardous mains voltages present within
this unit. Primary heatsink is live. Please see enclosed
'Astec Installation and Operating Instructions'. Use of
optional cover kit is recommended for safe operation.
110 Watts
Single Output
IEC801-4 level 3
(or 26-03-4050)
(or 26-03-4090)
(or 08-58-0189)
Output Specifications
80 W for convection;
Maximum
110 W with 30 CFM forced air
total wattage
± 5% minimum
Adjustment
range
20 ms at full load and 115 VAC
Hold-up time
nominal line
Short circuit protection on all outputs.
Overload
Auto recovery. Total power limited @
protection
110% to 135% above peak rating
5V output: 5.7 to 6.7 Vdc. Other
Overvoltage
outputs 10 to 25% above nominal
protection
output; recycle AC to reset
Safety
VDE
0805/EN60950 (IEC950)
UL
UL1950
CSA
CSA 22-2-234 Level 3
NEMKO
EN 60950/EMKO-TUE (74-sec) 203
BABT
EN60950/BS7002
CB
Certificate and report
This product is CE marked following
the provisions of the Low Voltage
Directive 73/23/EEC
Power OK
SK202
pin2 common
Power OK signal;-TTL compatible signal
goes high 50-150ms after switch on. Goes
low >1.5 ms before loss of regulation
Remote Sense
SK201
pin2 -sense
This power supply has a connector for output
remote sense. This can be used to
compensate for cable voltage drops of up to
0.5V. If this feature is not used the power
supply reverts to internal local sense.
Protected against reverse connection.
Cover
Cover available
Overall dimensions with cover -
193.5 (7.62) x 115.6 (4.55) x 63 (2.48).
Total power with cover derates to:- 70W
convection, 90W with 30CFM forced air.
Fusing
Input fuse 4A 20mm Quick Acting HBC
mains fuse - only replace with same type
and rating to maintain safety standards.
pin1 POK
1
2
1
pin1 +sense
2

Publicité

loading

Sommaire des Matières pour ASTEC LPS110 Serie

  • Page 1 Fusing this unit. Primary heatsink is live. Please see enclosed Input fuse 4A 20mm Quick Acting HBC ‘Astec Installation and Operating Instructions’. Use of mains fuse - only replace with same type optional cover kit is recommended for safe operation.
  • Page 2 +24 V +48V Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.
  • Page 3 Fusible d’entrée 4A 20mm rapide HBC Refroidisseur primaire non isolé. Veuillez consulter la notice à remplacer par le même type et la d’installation ASTEC et les instructions d’utilisation. L’utilisation même valeur pour maintenir les du kit capot est recommandée pour l’utilisation en toute sécurité.
  • Page 4 +24 V +48V Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.
  • Page 5 Bedienungs Anleitung LPS110 Serie 110 Watt Einfach Ausgang Eingangs Spezifikationen Ausgangs Spezifikationen 85 VAC bis 264 Eingansbereich Maximale 80 W bei Konvektions- kühlung; 120 bis 370 VDC Ausgangsleistung 110 W bei 51m /Std (30 CFM) Luftkühlung. 47 - 440 Hz...
  • Page 6 +24 V +48V Astec Standard Power Europe Astec House, Waterfront Business Park, Merry Hill, Dudley, West Mids. DY5 1LX, UK. Tel: +44 (0) 1384 842211 Fax: +44 (0) 1384 843355 Astec France S.A.R.L. Les Arcades, 424, la Closerie Mont d'Est, 93194 Noisy Le Grand Cedex, France.

Ce manuel est également adapté pour:

Lps112-bLps113-bLps114-bLps115-bLps118-b