4-noks
Power Reducer RC
Troubleshooting
1) During the Power Reducer pairing procedure, the App displays the message "No
device found"
Check that the GREEN Led is off. If not, proceed to RESET the device (see table 2)
9
Check that the antenna has been fitted; if not, install as indicated.
9
There is insufficient radio coverage: install a repeater.
9
2) The power diverted to the Power Reducer never appears on the main screen of the
"Elios4you" App.
Make certain the thermal overload relay has not been tripped at the water heater/
9
storage tank.
Check that the GREEN Led on the Power Reducer is permanently alight. If not,
9
repeat the pairing procedure (see Installation)
Check that only the phase conductor of the system passes through the Current
9
Transformer: if both phase and neutral pass through, an error will be induced.
Check that the CT has not been damaged internally during installation: the core
9
must not be cracked or have pieces missing.
Check that the resistive load has been connected correctly.
9
Technical specifications
General
App-controlled power reducer for single-phase resistive loads
specifications
(typically an electric water heater)
Power supply
230Vac (± 10%) 50Hz
Output
3.0kW max, resistive
ZigBee standard 2.4GHz; radio range 20 m indoors / 50 m
outdoors. Note: the distance is indicative and may vary with
Radio specifications
ambient conditions (dimensions and material of walls / floor
slabs, etc.)
/
2 x visual alarm, system power on, system with Boost
Status display
activated.
/
1 x LED with brightness proportionate to power reduction
Protection
Internal fuse rated 20A (FF632320)
/
Screw terminals for power supply
Connections
/
Screw terminals for power supply to resistive load
Antenna
External antenna ANT-RP-SMA
/
Operating conditions: -5 °C to +40°C; <80% R.H., non-
condensing
Ambient parameters
/
Storage conditions: 0°C to +70°C; <80% R.H., non-
condensing
Degree of protection
IP20
Directives 2014/30 EU; 2014/35 EU; 99/5 EEC; 2011/65 EU;
EMC (Electromagnetic Compatibility); EN 55014-1; EN55014-2;
Conformity
EN61000-3-2; EN61000-3-3; EN61000-6-2; EN61000-6-3;
EN60335-1; EN60335-2-21
Dimensions
280 x 405 x 70.5 mm
(L x H x D)
Conformity
All models comply with Directives 2004/108 EC and 2006/95 EC, and with
Directive 99/5 EEC. The declaration of conformity can be viewed at:
noks.com/download.
Safety and disposal
Electrical and electronic equipment requiring sorted collection, in compliance
with local regulations on waste disposal currently in force.
Astrel Group reserves the right to change product specifications without notice
4-NOKS is a brand of ASTREL GROUP
ASTREL GROUP SRL
/
Via Isonzo, 21/E
/
34070 Mossa (GO) Italy
/
www.astrelgroup.com
/
www.4-noks.com
EN
/
Installation and instruction manual
Installation diagram (fig. 3)
Main meter
N
L
Elios4you Smart
/ Elios4you [Pro] Smart
V
www.4-
* Measurements cannot be taken
Water heater / hot water
with a current clamp applied
storage tank
to the conductors on the resistive load side
Wireless connection
Terminal 3
L
N
Terminal 1
A
B
Terminal
2
CT (Current
transformer)
Ø 2,5 mm
Ø 2,5 mm
2
2
INCORRECT*
1
2
Generation meter
N
L
Main thermal-magnetic
and differential switch
L
N
Household appliance
Thermal-magnetic 20A
N
L
CORRECT*