Power Reducer RC
Code
Name
PR-RC
Power Reducer RC
Read and keep these instructions
General description
The Power Reducer RC is a wireless device which, when combined with Elios4you Smart
(single-phase and three-phase), provides the facility of producing hot water using photovol-
taic energy generated on site, without ever drawing power from the grid.
Thanks to the wireless connection with the Elios4you Smart or Elios4you [Pro] Smart con-
troller, the Power Reducer RC is easily installed near to the water heater or storage tank,
without any need for additional wiring.
Minimum requirements
Elios4you Smart
9
Elios4you [Pro] Smart (Elios4you Pro + Pro Smart)
9
Free "Elios4you" App updated to the latest version available
9
Contents of the pack
1 x Power Reducer RC
9
1 x internal wired CT
9
1 x external antenna (to assemble)
9
Safety warnings
All hardware connections must be made by a person who is suitably qualified and aware of
the risks associated with installation, observing minimum standards of safety, and with the
equipment isolated from the power supply.
The user accepts all responsibilities and risks connected with the steps of installing, con-
figuring and using products to the end of obtaining the benefits and advantages they afford.
The liability of the Astrel Group in respect of its products is regulated by the Astrel Group
General Conditions of Sale (published on the company's website www.astrelgroup.com).
Do not disassemble, open up or attempt to repair the product. Opening up a sealed compo-
nent has the effect of invalidating the warranty.
Caution
IMPORTANT: The Power Reducer RC can be connected only to a purely resistive load; it
cannot be used with water heaters having built-in electronic control circuit boards, but must
be connected directly to the heating element and the relative electromechanical thermostat.
Warnings for installation (fig. 3)
WARNING: Use TERMINAL 1 (connector A and B) only to connect the two wires supplying
power to a resistive load. Any other kind of connection (e.g. sharing A or B with L or N) is
likely to cause electrical damage internally, and will invalidate the manufacturer's warranty.
WARNING: install a fuse or thermal magnetic breaker rated 20A to protect the device.
WARNING: Before cutting the cable, ensure that the water heater is not powered up.
WARNING: switch on the Power Reducer RC only with the cover closed.
4-NOKS is a brand of ASTREL GROUP
ASTREL GROUP SRL
/
Via Isonzo, 21/E
/
34070 Mossa (GO) Italy
/
www.astrelgroup.com
/
www.4-noks.com
EN
/
Installation and instruction manual
Installation
Prior to installation
1)
Check that the distance at which the Power Reducer RC is installed from the load
will be compatible with the radio range indicated in the technical specifications.
Caution: the radio range between the two devices will typically guarantee
transmission through a suspended floor slab or a load-bearing wall. If radio
coverage proves to be unavailable, use a repeater.
2)
Check that the "Elios4you" App installed on the mobile device is communicating
correctly with the Elios4you Smart / Elios4you Pro device
Fixing
3)
Position the Power Reducer RC in such a way that it will always be properly
ventilated. Install the device vertically (cable glands facing downwards), ensuring a
clearance of at least 7 cm, top and bottom (fig. 2).
4)
Fix the Power Reducer RC to the wall with Ø 6 mm masonry plugs, using the holes
indicated in fig. 2
5)
Fit the antenna supplied (ANT connector, see fig. 2)
Connections
6)
Shut off the electricity supply to the installation site and check that the
water heater / storage tank is not powered up
7)
Make the electrical connections as indicated in the installation diagram (fig. 3 rear)
Caution: The current transformer (CT) must be clamped only on the phase line (L).
The direction is not important
8)
Refit and secure the protective cover
First power-up
9)
Switch on the Power Reducer RC
10) On power-up, check that all of the indicator Leds (fig. 1) blink for
2 seconds, before going dark and remaining off.
11) Start the "Elios4you" App to enable the "Power Reducer" function:
A) Menu
> System parameters > Peripherals management > select "Power
Reducer" > set load parameters (Nominal power of load/heating element)
B) Menu
> Preferences > Check (9) "View Power Reducer" and "Power
Reducer Detail"
Indicator LEDs
Pulsante
280 mm
70,5 mm
Fig. 1
Fig. 1
C) Menu
> Smart RC > "Add Smart RC device" > "Start procedure" and press
the Power Reducer button when prompted by the App.
D) For more information:
www.4-noks.com/tutorial
12) When the Power Reducer RC is paired correctly with the Elios4you Smart, the
GREEN Led remains permanently alight. The YELLOW and RED Leds indicate
normal operation (see table 1)
Check installation
13) Select Boost mode by pressing the button on the Power Reducer RC (see fig. 1)
14) Open the "Elios4you" App
15) Check the quality of the signal between Elios4you and Power Reducer RC by way
of the icon
alongside the Power Reducer symbol
16) Verify that the power diverted to the heating element corresponds to that
effectively set via the App.
17) Press the Power Reducer icon and activate the Timer function
Operation
In use, the response of the Power Reducer RC depends on the commands received from
the "Elios4you" App
Boost function: forces the connected heating element to switch on at 100% power. Can
be activated:
By pressing the button (fig. 1): The Boost function remains active for one hour, or
9
until the button is pressed again/a new command is received from App.
By way of the App: manually or setting the Timer function
9
(see guided procedure on www.4-noks.com/tutorial)
Timer function
: allows the user to program forced on/off cycles of the resistive load,
irrespective of surplus power from the photovoltaic source.
Ø 6 mm fixing holes
1
Clearance
7 cm minimum
ANT connector
1
2
3
4
14 cm
Clearance
7 cm minimum
Fig. 2
Fig. 2
Response of Leds (table 1)
Led
Status
Meaning
Permanently
Device paired
alight
Green
Slow blink (1Hz)
Pairing procedure in progress
Off
Device not paired
Blink
Output power split
Permanently
Output power 100% (maximum power
Yellow
alight
consumption)
Off
Output power = 0
Off
Boost function not active
Red
Permanently
Boost function activated by button (load on at
alight
100% for one hour)
Operation of button (table 2)
Function
Command
Meaning
Press briefly
Activates pairing of Power Reducer RC with
Pairing
(1 second
Elios4you Smart. GREEN Led blinks.
approx)
Press the button and hold for at least 10 seconds
Reset
Press and hold
to restore the factory settings
Activation of Boost function. In this condition, the
Boost
Press briefly
connected heating element is activated at 100%
load, irrespective of the grid power available.
+05T407150R1.1 Power Reducer RC Instruction Manual IT-EN-FR-DE
Astrel Group reserves its rights to make changes or variations to its own products without any prior notice
/
11.11.2016
/
p. 3/8