saia-burgess CXL 20 Instructions D'utilisation page 5

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating instructions
LCD Display counters
Type CXL 20/21/24/26
The CXL display counters are battery-powered. They
are controlled by contact or voltage pulses. They may
be used in various applications, like e. g.
totalising, parts counting, position acquisition,
Overview
Model
Operating mode
CXL201VHX
Count
CXL201VKX
CXL201VGX
CXL211VHX
Cnt.Dir/Up.Dn
CXL211VJX
CXL211VGX
Up.Dn
CXL261VGX
Cnt.Dir
CXL241VHX
Quad/Quad2
CXL241VJX
Table 1
DC input modes:
Count:
Fast and slow counting inputs
INP A:
Fast counting input
INP B:
Slow counting input
Cnt.Dir:
Counting and counting direction input
INP A:
Counting input
INP B:
Counting direction input
Up.Dn:
Differential counting input
INP A:
Adding counting input
INP B:
Subtracting counting input
Quad:
Phase discriminator input
INP A:
0° counting input
INP B:
90° counting input
Quad2:
Phase discriminator input with
pulse doubling
INP A:
0° counting input
INP B:
90° counting input
Each edge of INP A is counted.
differential counting, etc. In addition, the various
models with specific input types may be extended
using control inputs to select operatin modes and set
for almost any application thanks to adjustable opera-
ting modes.
Counting inputs
INP A
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC AC/DC 30 Hz
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
10 ... 260 V AC/DC
AC/DC
10 ... 260 V AC/DC
AC/DC
00 ... 0,7 V DC
NPN
04 ... 30 V DC
PNP
Options:
AC input modes:
Count:
Cnt.Dir:
Up.Dn:
INP B
07 kHz 00 ... 0,7 V DC
12 kHz
00 ... 0,7 V DC
10 ... 260 V AC/DC
07 kHz
00 ... 0,7 V DC
12 kHz
04 ... 30 V DC
30 Hz
10 ... 260 V AC/DC
30 Hz
10 ... 260 V AC/DC
03 kHz
00 ... 0,7 V DC
06 kHz
04 ... 30 V DC
X = N: no backlight
X = L: with backlight
Counting and reset inputs
INP A:
AC/DC counting input
INP B:
AC/DC reset input
Counting and counting direction input
INP A:
AC/DC counting direction input
INP B:
AC/DC counting input
Differential counting input
INP A:
AC/DC subtracting counting input
INP B:
AC/DC adding counting input.
NPN
30 Hz
NPN
AC/DC
0–
NPN
07 kHz
PNP
12 kHz
AC/DC
30 Hz
AC/DC
30 Hz
NPN
03 kHz
PNP
06 kHz

Publicité

Table des Matières
loading

Table des Matières