System Startup
1. As needed, update your scheduled initiation and
termination times. See DDT40 or DTAV40 instructions
or www.intermatic.com for programming instructions.
2. Snap the provided dead front cover into place, if
applicable. See FIG. 10.
3. Re-apply power to the unit.
4. The control will sense the number of probes connected.
Note: Observe the blue LED during startup in order to
verify that the ICUBE™ module registers the correct
number of thermistor probes. The blue LED will flash
once for each recognized
5. See TABLE 1 and FIG. 11 or FIG. 12 to verify proper
operation of the ICUBE™ module.
Blue LED
Green LED
Red LED
FIG. 11
LEDs (Enclosed Model Shown)
ICUBE™ Adaptive Defrost Module
probe.
FIG. 10
Attach the Provided Dead Front
Mode
LED
Green LED
ON
A
Red LED
OFF
Green LED
OFF
Red LED
OFF
B
Green LED
ON
Red LED
ON
ON
OFF
1 flash/1 second
A/B
Blue LED
5 flashes/
10 seconds
1-4 flashes/
10 seconds
TABLE 1 LED Status Indicator Table
Blue LED
Green LED
Red LED
5
Diagnostics
Status
Control Mode
Refrigeration mode active
Defrost mode active
Refrigeration mode active
Defrost mode active
Next scheduled defrost to be
delayed (efficiency mode)
Next scheduled defrost active
Calibration mode
Thermistor sensor error
Only occurs at startup to
indicate the number of sensors
connected to the control