Télécharger Imprimer la page

Takex TX-114TR Notice D'instructions page 7

Capteur exterieur irp double zone

Publicité

When the unit is mounted on unlebel wall,back
tamper switch could be kept turninig on. In this case,
use B.T.Killer which can disable the function ©.
7
WIRING
Terminal Confi guration
[COMMON BATTERY]
Common for TX-114TR/FR/SR and Transmitter
A
When connecting this unit to the transmitter
which has no input terminals for tampers, connect
alarm and tamper terminals of this unit in series.
Both alarm and tamper signals can be outputted.
(Select N.C. for contact output.)
SUPPLY VOLTAGE
•3 to 9VDC Alkaline or Lithium Battery (polarity)
•Current Consumption
(Except test-mode period)
25 μA (TX-114TR/114SR)
35 μA (TX-114FR)
ALARM
•Solid State Switch form N.O./N.C. selectable
•10VDC · 0.01A Max
[Detection Alarm] OR [Trouble Alarm]
TAMPER
•Solid State Switch form N.O./N.C. selectable
•10VDC · 0.01A Max
[Front Tamper] OR [Back Tamper]
[SEPARATE BATTERIES]
Each for TX-114TR/FR/SR and Transmitter
Power supply needs same or higher voltage than
B
that for transmitter
When a connected transmitter doesn't accept the
C
output, to connect the
terminal of TX-114TR/
FR/SR and the negative pole of the battery for the
transmitter may solve the problem.
Wiring insertion
(1) Put the wire through the wiring holes and connect
them to the battery and transmitter and the
terminals.
(2) Fix the transmitter and battery on the back box
with the adhensive sheets.
* When connecting this unit to the transmitter which
has no input terminals for tampers, connect alarm
and tamper terminals of this unit in series.
Both alarm and tamper signals can be outputted.
(Select N.C. for contact output.)
8
INSTALLATION
Before the installation
Read
PRECAUTIONS before the installation.
2
(1) Loosen the cover locking screw.
(2) Remove the cover.
(3) Loosen the body locking screws.
(TX-114TR/114FR only)
(4) Remove the body unit. (TX-114TR/114FR only)
Wall Mounting
TX-114TR/114FR
(1) Break 2 knockouts on the mounting base.
(2) Install the base to the wall with 2 tapping screws.
[Installed pitch: 3.29" (83.5mm)]
TX-114SR
(1) Install the base to wall with 2 tapping screws.
[Installed pitch:8.25" (209.5mm)]
Pole Mounting
TX-114TR/114FR
Use the pole attachment "BP-32" (sold separately)
Use a 1.66" to 1.75" (38mm to 45mm) outer diameter
pole
(1) Break 4 knockouts on the mounting base.
(2) Attach 2 pole mounting brackets to the backside
of the base with 4 tapping screws.
(3) Place the U brackets on the back of the pole.
Attach the mouting base to the U bracket with
pole mounting screws.
(4) Refer to
7
WIRING and connect wires to the
terminals.
TX-114SR
Use the pole attachment "BP-22" (sold separately)
Assembling
(1) Attatch the Body unit to the Mounting Base.
(TX-114TR/114FR only)
(2) Fasten the Body locking screws.
(TX-114TR/114FR only)
* Carry out OPERATION CHECK with the cover
detatched.
(3) Replace the cover.
(4) Fasten the Cover locking screw.
OPERATION CHECK
• Refer to the
DETECTION AREA, and set the
3
horizontal angle and detection distance.
• Make functional settings in accordance with the
purpose of use of this unit.
• Connect the battery to the unit after which approx.
1 min warm up period starts.
• Attach the cover to the unit and fi x it by tightening
SPECIFICATIONS
Model
Detection system
Passive infrared
When horizontal detection
Angle: 90°
Coverage
Detection distance: 40' (12m)
Horizontal zone: 7zones
Downward zone: 7zones
Horizontal: 90 degrees
Coverage adjustment
Detection distance: 6.6' to 40' (2m to 12m)
(Adjustable by changing the vertical angle of downward curtain)
Supply voltage
3V to 9VDC Alkaline or Lithium Battery
Operation voltage
2.3V to 10VDC (Battery)
25 μA for detection
Current consumption
5mA/3V (Test mode)
Solid State Switch N.C./N.O. selectable
10VDC · 0.01A Max
Alarm output
One shot output when detecting human beings (approx. 2sec)
Tamper output
Operation
Real time output
•when the cover is detatched from the unit
•when the unit is detatched from the installed wall or pole. (TX-114TR/TX-114FR Only)
Trouble output
Real time output when the unit suffers functional trouble. (from terminal of Alarm)
Red LED
•Blinking for approx. 1min at warming-up
Operation LED
•Lighting for 1sec at detection during walk-test (LED lights only in a test-mode)
•Blinking when trouble alarm is issued (Lights once every 5 sec)
Sensitivity adjustment
Approx. 30% to 170% (By volume)
Pulse count
1/3 selectable with a dip switch
Alarm prohibition time
10sec/120sec/300sec/900sec selectable with dip switches
Detection mode
Ambient temperature
-4°F to +122°F (-20°C to +50°C)
Mounting position
Indoor/Outdoor [Wall or Pole]
Weight
14oz (400g)
Appearance
Body: AES resin
Limited Warranty:
TAKEX products are warranted to be free from defects in material and workmanship for 12 months from original
date of shipment. Our warranty does not cover damage or failure caused by Acts of God (including inductive surge by
lightning), abuse, misuse, abnormal usage, faulty installation, improper maintenance or any repairs other than those
provided by TAKEX. All implied warranties with respect to TAKEX, including implied warranties for merchantability
and implied warranties for fi tness, are limited in duration to 12 months from original date of shipment. During
the Warranty Period, TAKEX will repair or replace, at its sole option, free of charge, any defective parts returned
prepaid. Please provide the model number of the products, original date of shipment and nature of diffi culty being
experienced. There will be charges rendered for product repairs made after our Warranty period has expired.
Solve possible problems according to the following table. If normal operations cannot be
TROUBLESHOOTING
restored by this means, contact either the dealer from whom you bought the unit or TAKEX.
Trouble
•Battery is unconnected or low battery.
• Cover is shielded by substances (including
glass).
•Improper area adjustment.
• Not yet about 1minute after a battery is connected
Completely inactive
to the unit. (Operation LED is flickering.)
• The voltage of powersupply is lower than that
for transmitter.
•Incorrect polarity of powersupply
•Improper setting of output form
•Improper area adjustment.
•Cover face is soiled with dust or water drop.
Sometimes inactive
• Detection occurs within the signal prohibition
time set by a dip switch.
• Something moving in protected area or too
rapid temperature variations.
• Large electrical noise source such as power
machine nearby or its wiring close to that of
sensor.
• Intense refl ection of sun light or head light
Activated when no person
shining on the sensor.
has passed
• Reflective lights such as sun light or head
light affect the downward zone.
•Improper installation of the sensor.
• Detection distance of the downward zone is too long. •Readjust the detection distance.
• Cars or motor bikes located at the front of
detection area may activate the sensor.
LED lights on once every
• The unit suffers functional trouble. (Trouble
5 min though the unit is
signal is issued.)
not in a test mode
MAINTENANCE
•To clean the device, use a soft, wet cloth and then wipe off any water drops.
If the device is particularly dirty, dip the soft cloth in the water that contains a weak neutral detergent. Wipe
the device gently with the cloth, then wipe off any detergent that remains. Do not use substances such as
thinner or benzene. (The plastic parts may deform, discolor or change their properties.)
•Perform operation checks on a regular basis.
7
the cover locking screw.
(After the warm up time is over and the cover is
attached to the sensor, the unit will be in a test mode
for about 5 min.)
• After the warm up time is over, operate a walk test
and check the location and size of the detection area
through the LED.
• If necessary, readjust the angle and distance of
the detection area as well as sensitivity and pulse
count.
* Make sure that there is no undesirable detection of
traffi c including vehicles if there is a path or road at
the front of detection zone.
TX-114SR
TX-114TR
19.6oz (560g)
Lens: PE resin
Check
•Connect battery or replace battery.
•Remove the substances.
•Readjust the protection area setting.
•Allow for warming up time (about 1min.)
•Use same or higher voltage than transmitter.
•Change the polarity.
•Select the correct setting.
•Readjust the protection area setting.
•Clean the cover with soft cloth.
• If the sensor sends a signal after the
prohibition time is over, its function is normal.
•Remove the cause.
•Relocate the device.
• Relocate the device. Readjust the protection
area setting.
•Remove refl ective objects.
•Readjust the protection area setting.
•Install the sensor vertically.
• Readjust the area setting and range adjustment
so that there is no such undesirable detections.
•Check the function of the sensor.
TX-114FR
2sets of
TX-114SR / TX-114TR
sensors
35 μA for detection
AND/OR selectable
21.7oz (620g)
Corrective Action

Publicité

loading

Ce manuel est également adapté pour:

Tx-114frTx-114sr