AirKing LIN34 Instructions Importantes – Mode D'emploi

Revêtement avec puissance
Les langues disponibles

Les langues disponibles

IMPORTANT INSTRUCTIONS -
Models: LIN34, LIN40,
LIN46, LIN58
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
GENERAL SAFETY INFORMATION
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you
have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American
Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY
EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT
EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO
ATTICS, CRAWL SPACES, OR GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
6728024 Rev. C 8-10
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
WARNING:
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING:
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambéing food (ie. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING:
THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I.
II. The fire is small and contained in the area where it started.
III. The fire department is being called.
IV. You can fight the fire with your back to an exit.
WARNING:
DUCTWORK.
www.airkinglimited.com
Powered Liner
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
TO REDUCE THE RISK OF INJURY TO PERSONS IN
You know you have a Class ABC extinguisher, and you
already know how to operate it.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
1 of 8
Table des Matières
loading

Sommaire des Matières pour AirKing LIN34

  • Page 5: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Revêtement avec Modèles : LIN34, LIN40, puissance LIN46, LIN58 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 6 LORS DE DECOUPE OU DE PERCAGE DANS UN MUR NE PAS ENDOMMAGER DE FILAGE ELECTRIQUE OU AUTRES UTILITES DISSIMULEES. Chapeau 1. Taillez un trou d’une grandeur appropriée pour l’armoire dans lequel le revêtement de toit sera monté (Figure 1) : Modèle LIN34: 34.5 po x 19.375 po Modèle LIN40: 40.5 po x 19.375 po Modèle LIN46: 46.5 po x 22.625 po Adaptateur Modèle LIN58: 46.5 po x 22.625 po de sortie Chapeau 34.5 po/40.5 po/...
  • Page 7 SECTION 5 Câblage Canal du AVERTISSEMENT : haut TOUTES LES CONNEXIONS DOIVENT ÊTRE FAITES EN CONFORMITÉ AVEC LES CODES ÉLECTRIQUES LOCAUX OU NATIONAUX. SI VOUS N’ÊTES PAS FAMILIER AVEC LES MÉTHODES D’INSTALLATION DE CÂBLAGE Canal du ÉLECTRIQUE, RECOURREZ AUX SERVICES D’UN ÉLECTRICIEN QUALIFIÉ. 1. Enlever les deux vis du couvercle du compartiment Connecteur à fils de câblage pour obtenir l’accès au compartiment de...
  • Page 8: Guide De Dépannage

    DE SÛRETÉ, BEAUCOUP DE COMPOSANTS ÉLECTRONIQUES ET LA PLUPART DES COMPOSANTS DES CHAUFFAGES NE SONT PAS À LA DISPOSITION DES CONSOMMATEURS POUR L'INSTALLATION OU LE REMPLACEMENT. # de pièce # Qté. Description de remplacement 1 1 Adaptateur de sortie vertical (LIN34, LIN40) 5S1136141 1 Adaptateur de sortie vertical (LIN46, LIN58) 5S1136143 2 1 Boîte de filage...

Ce manuel est également adapté pour:

Lin40Lin46Lin58

Table des Matières