Jandy Laminar Jet JLLED4C Serie Manuel D'installation Et D'utilisation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Page 4
ENGLISH
To minimize risk of severe injury or death the filter and/or pump should not be subjected
to the piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These
requirements are generally not intended to apply to the pool equipment such as filters or
pumps.
Jandy pool equipment is pressure tested at the factory.
If however this WARNING cannot be followed and pressure testing of the piping system
must include the filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING
SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings and system accessories to ensure they are
properly installed and secured before testing.
• RELEASE ALL AIR in the system before testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C).
• Limit test to 24 hours. After test, visually check system to be sure it is ready for
operation.
NOTICE: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult equipment
manufacturer.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
which could result in serious injury or death. A Ground Fault Circuit Interrupter (GFCI) for 120 Volt transformers
should be used if required by the transformer manufacturer or if required by the local applicable code and/or
Authority Having Jurisdiction (AHJ). When a GFCI is used, the conductors on the load side of the GFCI circuit
shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors are
also protected by a GFCI. Refer to local codes for complete details.
Jandy
Laminar Jet | Installation and Operation Manual
®
WARNING
WARNING
SAVE THESE INSTRUCTIONS

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Laminar jet jlfbr serie

Table des Matières