Connection layout for SPS 220 or SPS 330 regulator
Only make direct connections. Never use other terminal blocks or existing electrical circuits.
The regulator has to be put as near up to the battery as possible, sheltered from impacts and humidity.
Use the black provided cable* or 2,5 -
4 mm
anti-U.V. cable.
2
Connect with the provided 
thermofusion fittings or with sol-
derless 
Warning SPS 220:
Protect with a 20 Amp fuse.
Warning SPS 330:
Protect with a 30 Amp fuse.
ALD-12291
The fuse has to be put as near up to the battery as possible.
blue
brown
TOIT
Use the blue provided cable*
or 4 - 10 mm
cable.
2
blue
brown
cell-battery
ALDEN DECLINES ALL RESPONSIBILITY IF THE INSTALLATION IS NOT DONE
ACCORDING TO THESE INSTRUCTIONS.
Use the provided
terminals
Solar computer option
Use the 4 - 10 mm
cable (long. max. : 2 m.)
Towards the + input
of the start battery
Optional temperature sensor
AES option only for SPS 330
Place the switches as indicated on the diagrams
according to the type of battery
SPS 330