Regulations To Be Observed; Chimney Design - Olsberg Tolima PowerSystem Compact 23/557 Instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Stove Tolima PowerSystem Compact
Instruction
Contents
Foreword ................................................. Page
Technical Data ..................................................... 9
Regulations to be observed ............................... 9
Chimney design ................................................... 9
Combustion air supply ..................................... 10
Installing the stove .............................................10
Assembly sequence .......................................... 10
Operation ...................................................... 10-11
Cleaning ............................................................. 13
What to do if? .................................................... 13
Foreword
This stove is a top quality modern heating technology
product.
A large degree of user comfort and high fuel utilisa-
tion enable it to be used as high quality space heat-
ing, without having to do without the cosy atmos-
phere of an open fire.
Proper installation and correct handling and care are
indispensable for problem-free operation and a long
service life. Please therefore observe all the infor-
mation given in these instructions. We are convinced
that you will then derive a great deal of pleasure from
this stove.
Please keep these instructions in a safe place so that
you can read through them at the start of each heat-
ing period.
Should you find any transport damage, please report
it to your supplier immediately as otherwise it will not
be possible to correct the damage free of charge.
Technical Data
- Nominal thermal output
- Room heat output
- Height to top edge of connector pipe with
the connection at the top
- Connection pipe
- max. Weight
- Connection combustion air
- Operating Mode
GB
9
[kW]
6,0
[kW]
6,0
[mm]
1311
∅ 150
[mm]
[kg]
325
∅ 125
[mm]
Intermitting burning
Page 9 - 13

Regulations to be observed

Local and building law regulations
The stove must be installed by a professional
and connected to the chimney.The specific na-
tional regulations for safe installation of the con-
nector must be complied with.
The stove complies with EN 13240.
The heating stove's fire door is self-closing; it is
therefore approved for connection to chimneys with
multiple connections.
It must be ensured that adequate combustion air is
available. If necessary, it must be fed from the out-
side.Please contact your local master chimney
sweep, specialist trader or skilled tradesman for pro-
fessional advice.

Chimney design

The chimney design is according to DIN
and -2 or to the specific national regulations. The
chimney must comply with the temperature class
T400.
Necessary data
Closed operation
with billet wood / wood briquettes:
- Nominal thermal output ...........................6,0 / 6,0 kW
- Waste air mass flow rate ......................... 5,1 / 5,4 g/s
- Waste air temperature at
connection duct..................................... 305 / 315 °C
- Minimum delivery pressure at
nominal thermal output .............................12 / 12 Pa
23/557
-1
9

Publicité

Table des Matières
loading

Table des Matières