PEDESTAL PLATE HEATER
Certified to comply with 2015 particulate emission standards for single burn rate heaters. Not approved
for sale after May 15, 2020. This single burn rate wood heater is not approved for use with a flue damper.
TESTED TO UL 1482-11 (R2015), ULC-S627-00, and ASTM 2780/Method 28R
Read All Instructions Carefully Before Starting The
Installation or Operating This Heater.
Improper Installation Could Void Your Warranty!
Please read this entire manual before you install
and use your new room heater. Failure to follow
instructions may result in property damage, bodily
injury, or even death.
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU
TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
French version is available for download from the US Stove website: http://www.usstove.com
La version française est disponible pour téléchargement à partir du site US Stove: http://www.usstove.com
Owner's Manual
MODEL: 2016E (B)
U. S. ENVIRONMENTAL PROTECTION AGENCY
CAUTION!
SAVE THESE INSTRUCTIONS
UNITED STATES STOVE COMPANY
227 Industrial Park Road
South Pittsburg, TN 37380
SAFETY NOTICE:
If this heater is not properly installed, a house fire
may result. For your safety, follow the installation
instructions. Contract local building or fire
officials about obtaining permits, restrictions and
installation requirements in your area.
Do not use this heater in a Mobile home or trailer!
Report # 0215WS045E
0215WS045S
852531D-2015G

Publicité

loading

Sommaire des Matières pour KING 2016E

  • Page 1 Owner's Manual PEDESTAL PLATE HEATER MODEL: 2016E (B) U. S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2015 particulate emission standards for single burn rate heaters. Not approved for sale after May 15, 2020. This single burn rate wood heater is not approved for use with a flue damper.
  • Page 2 CONGRATULATIONS! You've purchased a heater from North America's oldest burn rate that must not be altered. It is against federal manufacturer of wood burning products. regulations to alter this setting or otherwise operate this By heating with wood you're helping to CONSERVE wood heater in a manner inconsistent with operating ENERGY! instructions in this manual.
  • Page 3 Safety Rules SAFETY NOTICE: If this heater is not properly installed a house fire may result. Do not use make-shift compromises during installation. Clean your stove frequently to reduce soot, creosote and ash accumulation. For your safety, follow the installation directions. Contact local building or fire officials about restrictions, permits and installation inspection requirements in your area.
  • Page 4 Minimum Clearance To Combustible Walls Stove Clearances Side Wall 18" (457mm) Back Wall 12" (305mm) Ceiling Height 84" (2134mm) Closest Wall to Corner 12" (305mm) Wall to Chimney Connector (Alcove) 21" (533.4mm) Side Wall to Chimney Connector 22.25" (565mm) Back Wall to Chimney Connector 15"...
  • Page 5 Locating The Room Heater As A Location Is Selected, Keep The Following In Mind Keep the chimney connection as short as possible. Check Figures 2, 3, & 4. You should have at least The heater must have its own chimney flue. Do not the clearances shown from the heater and the connect any other appliance to the same flue.
  • Page 6 Mounting Cast-Iron Flue Collar This heater comes equipped with a cast-iron flue collar. Flue Collar - 40292 5/16-18 x 1-1/2" Bolts (3 req.) Weld Tab (3 req.) Gasket Blower Assembly ASSEMBLY INSTRUCTIONS DESCRIPTION PART NO. QTY. Step BLOWER ASSEMBLY MUST Blower Housing Back 25089B DISCONNECTED FROM THE SOURCE OF ELECTRICAL...
  • Page 7 CHIMNEY CONNECTION Take into account the chimney’s location to insure it is not too close to neighbours or in a valley which may cause unhealthy or nuisance conditions. Your chimney connector and chimney must have the same diameter as the stove outlet (6”). If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draft .
  • Page 8 Venting Into A Fireplace Many people may wish to convert an existing cooling so that the base, back and sides can be safely fireplace to heater use. Usually, safe connection placed in direct contact with combustible floors and of stovepipe to a masonry chimney requires more walls.
  • Page 9 "Fireplace" Installation FIREPLACE INSTALLATION with 8 inches of brickwork (solid masonry units) or 24 inches of stone. Connection of the stovepipe directly into the Install the stovepipe as far as possible into the existing masonry chimney over the fireplace opening thimble, but not past the inside of the flue lining.
  • Page 10 COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS Method A. 12” (304.8 mm) Clearance to Combustible minimum 6” (152.4) mm separation area containing Wall Member: Using a minimum thickness 3.5” (89 fiberglass insulation, from the outer surface of the mm) brick and a 5/8” (15.9 mm) minimum wall wall thimble to wall combustibles.
  • Page 11 Rules For Connector Pipe Installation 1. Crimped end of the pipe must be installed toward only in your wood stove. The wood should have dried the heater. The pipe should slide inside the flue for 9 to 15 months, such that the humidity content (in collar.
  • Page 12 burn well-seasoned wood. Higher burn rates are not longer, your wood is damp. always the best heating burn rates; after a good fire is If your wood hisses and water or vapor escapes at established a lower burn rate may be a better option the ends of the piece, your wood is soaked or freshly for efficient heating.
  • Page 13 CHIMNEY MAINTENANCE a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this • Failure to clean and maintain this unit as creosote makes an extremely hot fire. The chimney indicated can result in poor performance and connector and chimney should be inspected at least safety hazards.
  • Page 14 Key Part No. Description Qty. 891084 Handle Rod 891112 Feed Door Key Part No. Description Qty. 891108 Glass w/King Logo 89066 Firebrick (4-1/2 X 9) 88087 Door Glass Gasket 69458 Plug, Ash 891114 Top/Side Window Bracket 24103 Firebrick, Half (4-1/2 X 4-1/2)
  • Page 15 Brick Placement - (Top Inside View Of Firebox) BRICK BRICK 1. Insert right & left side firebrick as shown. 2. Insert rear firebrick as shown. 3. Insert bottom 1/2 firebrick and ash dump cover as shown. Wiring Diagram CAUTION: The blower assembly WARNING: do not route the supply must be disconnected from the cord near or across hot surfaces!
  • Page 16 Ashes - Removal And Disposal Whenever ashes get 3 to 4 inches deep in your plastic bag, no matter how long the fire has been firebox or ash pan, and when the fire has burned out. Coals have been known to stay hot for several down and cooled, remove excess ashes.
  • Page 17 Service Record It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. SERVICE PROVIDER Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions. Always use the manufacturer's specified spare part when replacement is necessary.
  • Page 18 Limited Warranty Plate Steel Heaters (Inserts, Freestanding, and Pedestal) The operation of this heater in a manner inconsistent with the owner’s manual will void the warranty and is also against federal regulations. United States Stove Company warrants to the original purchaser its products against premature failure of any component due to workmanship, quality, or materials as follows: TIME PERIOD: Firebox ............................
  • Page 19 How To Order Repair Parts / Comment Commander Des Pièces De Rechange This manual will help you obtain efficient, dependable service from your heater, and enable you to order repair parts correctly. Keep this manual in a safe place for future reference. When writing, always give the full model number which is on the nameplate attached to the heater.