INSTALLATION INSTRUCTIONS
Location
It is extremely important to install the compressor in a clean, dry, and well ventilated area. The compressor
must be placed on a firm, level surface where the surrounding air temperature will not be more than 100°F.
A minimum clearance of 18 inches between the compressor and a wall is required because objects could
obstruct air flow.
Electrical Installation
Wiring
1.
Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated
for at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for
this minimum.
2.
Use a slow blow fuse or a circuit breaker.
3.
This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug
illustrated in Figure 4. Make sure the product is connected to an outlet having the same configuration
as the plug. This product must be grounded. In the event of an electrical short circuit, grounding
reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped
with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into
an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Minimum Gauge of Extension Cord
25 ft.
14
Use of an extension cord may cause excess heat to
motor. This could lead to tripped breaker (at electrical
panel) or tripped thermal overload (on compressor
motor). If this occurs, eliminate extension cord and plug
compressor directly into electrical outlet. Avoid using
extension cords; use longer air hose(s) instead.
Do not locate the compressor air inlet near steam, paint spray, sandblast areas or any other
source of contamination. This debris will damage the motor.
All wiring and electrical connections should be performed by a qualified electrician.
Installation must be in accordance with local codes and national electrical codes.
Overheating, short circuiting and fire damage will result from inadequate wiring.
50 ft.
100 ft.
12
10
7
Grounding
Pin
Figure 4 - Grounding Method
Grounded Outlet