2. Place dehumidifier in a location that
does not restrict airflow through the
front of the unit or out of the louvers on
the left side of cabinet.
3. A dehumidifier operating in a basement
will have little or no effect in drying an
adjacent enclosed storage area, such
as a closet, unless there is adequate
circulation of air in and out of the area.
lt may be necessary to install a second
dehumidifier in the enclosed area for
satisfactory drying.
4. The dehumidifier must be installed on a
level floor that will support it with a full
bucket of water.
5. There should be a minimum of 12 in-
ches clearance around the dehumidifi-
er.

HOW IT WORKS

When the unit is started, the fan begins to
pull moisture-laden air across the dehumidi-

OPERATING INSTRUCTIONS

Allow the unit to reach room temperature
before operating. To begin operating the
dehumidifier, follow these steps:
Unit must be upright for one hour prior to
operating.
1. Plug the power cord into a properly
grounded 220 V AC outlet.
If the BUCKET FULL light is on, remove
the bucket and re-install to reset the
float switch.
fying coils. The coils condense or draw
moisture from the air, and air flows through
the side louvers into the room as dry, warm
air. Moisture removed from air is collected
in a bucket on the front of the dehumidifier.
The unit is designed to operate between
5°C (41°F) and 35°C (96°F). The unit will
not work properly if the temperature is out
of this temperature range, or the perform-
ance of the unit will fall greatly.
The "Compressor" circuit has an automatic
3 minute time delayed start if the unit is
turned off and on quickly. This prevents
overheating of the compressor and possible
circuit breaker tripping. Make sure the tank
is fitted correctly otherwise unit will not turn
on.
2. To turn the unit on, press the ON/OFF
button
. The unit will run in the fac-
tory setting of CONTINUOUS and high
fan speed. In the CONTINUOUS mode,
the unit will only display CO and not the
room humidity. It is recommended you
leave the unit running in the CONTINU-
OUS setting for the first three or four
days until the sweating and dampness
odors have stopped.