Télécharger Imprimer la page

Leister ROBUST Instructions D'utilisation page 13

Publicité

ROBUST device description
7
5
1. Air outlet
38
2. Air inlet
38
3. Motor
4. Terminal box
ROBUST installation
• The Robust blower must be fastened at the mounting foot (6) with four M6 bolts.
• Protect the blower from mechanical vibrations and shocks.
• The blower can be installed horizontally or vertically.
ROBUST operation
• The blower intake air temperature must be < 60 °C.
• When used in a dusty environment, a Leister stainless steel filter
must be fitted to the blower air inlet (2).
• The correct wiring for the mains voltage used must be configured
in the terminal box (4).
• The blower must be connected by a technical specialist. Ensure
that the direction of rotation is correct!
4
6
3
5. Terminal box cover
6. Mounting foot
7. Impeller housing
Circuit diagram in terminal
box cover (5)
220 – 254 V 380 – 440 V 220 – 254 V
W2
U2
V2
W2 U2
U1
V1
W1
U1
L1
L2
L3
L1
2
1
W2
U2
V2
V2
U1
V1
W1
V1
W1
L1
N
L2
L3
13

Publicité

loading

Produits Connexes pour Leister ROBUST

Ce manuel est également adapté pour: