Technical information sheet
2. Technical specifications
Dimensions
Installation
Power supply
Power consumption
Max. luminous flux
LED type
Protection rating
3. Installation
3.1. Electrical connection
Installation of this project involves a hazard of electric shocks. We strongly recommend you
contract a professional installer. An installation error can put you in danger and may irre-
versibly damage the product and the equipment connected to it.In compliance with the NF C
15-100 standard, pool lights installed in Volume 0 must always be powered by VLSV (Very low
safety voltage). Always cut off the power upstream before handling the electrical installation.
Risk of electric shock. Only connect to a circuit which is protected by a ground fault circuit
breaker . If you are not sure if these types of device are fitted, contact a qualified electrician.
3.2. Installation into 1.5'' standard wall conduit / nozzle
In case of installation into 1.5'' other brand nozzle, you can screw your light into the nozzle. For customization, you can use the
supplied cover with nozzle or install a Mini-BRiO 2 specific bezel (see catalog).
WARNING : in case of installation with Mini-BRiO 2 bezel, it is necessary to pass the wall through the bezel before screwing.
Reverse is impossible.
Mini Brio + & Switch M7 & X8
In a 2" brush socket (with trim PF10R294)
In a CCEI crossing PF10R291 (shell) or PF10R292 (liner)
Voltage: 12 V ~ (AC) / Frequency: 50Hz/60Hz
8W (Version X8 RGB) - 450 lm (depending on the colour)
PK10R314 (M7 +)
PF11R321 (M7 Switch)
PK10R315 (MK7 +)
PF11R322 (M7K Swtich)
PK10R313 (X8)
9 Power LEDs monochrome (3R/3G/3B)
PK10R323 (X8 Switch)
Risk group 1 (low risk) as per IEC62471:2006
The electrical connection must be performed dry, in a sealed
connection box whose cable glands must be tightened in order
to avoid any water infiltration.
Ø 49mm / depth 63mm
In a standard 1.5" brush socket
7W (Version M7) - 700 lm
3 Power LEDs Cold white (~6000°K)
3 Mid Power LEDs Warm white
(~3000°K)
v1.0EN
IP-68
2