E- Technical Features - SCS Sentinel HWAY MCO0093 Notice D'utilisation Et D'installation

Portail coulissant
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D7- Testing and checking
Make sure the general safety precaution «WARNING» has been carefully observed :
• Release the gearmotor with the proper release key.
• Make sure the gate can be moved manually during opening and closing phases with a force of max 390N
(40 kg approx).
• Lock the gearmotor.
• Using the key selector switch, push button device or the radio transmitter, test the opening, closing and stopping
of the gate and make sure the gate is in the intended direction.
• Check the devices one by one (photocells, blinker, key selector, etc.) and confirm the control unit recognizes
each device.
D8- Recognition of LED
LED indications
LED 1 Photocells
LED 2 Photocells

E- TECHNICAL FEATURES

E- TECHNICAL FEATURES
Remote controls
Channels
Frequency - Maximum transmitted power
Power supply
Security
40
EN
Descriptions
The LED1 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be careful, function H must be activated with a connected
photocell on PH1).
The LED2 turns on, when there is an obstacle between the photocells or an aligning
defect or a connection defect (Be careful, function J must be activated with a connected
photocell on PH2).
Photocells
Photocellule 1
4
433.92 MHz - power < 10mW
1 batterie lithium CR2032 included
rolling code technology

Publicité

Table des Matières
loading

Table des Matières