LEARNING THE PAUSE TIME
ATTENTION: the procedure can be started only when the
shutter is at rest, after having completed the cycle; the
closing limit switch need not be open.
USING THE START BUTTON
1. Close the shutter, so that the limit switch is not open upon
closing
2. Set DIP 1 and 2 to ON
3. Press the START button on the terminal board: the buzzer is
activated for 1 second, confirming the start of the procedure
4. Press the START button on the terminal board again when the
elapsed time matches that of the desired PAUSE: the LED and
the buzzer activate to confirm data storage
USING THE TRANSMITTER
1. Close the shutter, so that the limit switch is not open upon
closing
2. Set DIP 1 and 2 to ON
3.
- 1-key operation
Press the key of the transmitter that has been stored: the
buzzer is activated for 1 second, confirming the start of
the procedure
- 3-key operation
Press the OPEN key of the transmitter that has been
stored: the buzzer is activated for 1 second confirming the
start of the procedure
4.
- 1-key operation
Press the transmitter key again when the elapsed time
matches the desired PAUSE time: the LED and the buzzer
are activated to confirm data storage
- 3-key operation
Press the CLOSE key on the transmitter when the elapsed
time matches that of the desired PAUSE: the LED and the
buzzer are activated to confirm data storage
NOTE: radio or terminal block commands are not accepted
until DIP 2 is set to OFF
LEARNING THE OPERATION TIME
ATTENTION: the procedure can only be started when the
shutter is closed
USING THE START BUTTON
1. Close the shutter
2. Set DIP1 to OFF and DIP 2 to ON
3. Press the START button on the terminal board: the buzzer is
activated for 1 second, confirming the start of the procedure
4. The motor starts on opening
5. When the opening limit switch is reached, the motor stops
6. Press the START button on the terminal board: the motor
starts upon closing
7. When the closing limit switch position is reached, the motor
stops: the LED and the buzzer are activated to confirm data
storage
USING THE TRANSMITTER
1. Close the shutter
2. Set DIP1 to OFF and DIP 2 to ON
3.
- 1-key operation
Press the key of the transmitter that has been stored: the
buzzer is activated for 1 second, confirming the start of
the procedure
- 3-key operation
Press the OPEN key of the transmitter that has been
stored: the buzzer is activated for 1 second confirming the
start of the procedure
4. The motor starts on opening
5. When the opening limit switch is reached, the motor stops
6.
- 1-key operation
Press the transmitter key again: the motor starts upon
closing
- 3-key operation
Press the CLOSE key on the transmitter: the motor starts
upon closing
7. When the closing limit switch position is reached, the motor
stops: the LED and the buzzer are activated to confirm data
storage
RESET
To reset the control unit parameters to the factory settings,
proceed as follows:
1. Remove power on the control panel
2. Set DIP 1-3 to OFF and DIP 2-4 to ON
3. Remove the connections on terminal 11 (COMMON)
4. Restore the power supply: the LED and the buzzer are
activated to confirm the deletion of data
5. Restore the connections on terminal 11 and the position of
the DIPs as before the procedure
- 9 -