G INTRODUCTION
This instruction sheet provides you with the information required
to safely own and operate your Little Giant pump. Retain these
instructions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. Little Giant pumps are carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your pump carefully to ensure that no damage
occurred during shipment. If damage has occurred, please con-
tact the place of purchase. They will assist you in replacement or
repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
During installation, follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA).
This pump is supplied with a grounding conductor and/or ground-
ing-type attachment plug. To reduce the risk of electric shock,
ensure that it is connected to a properly-grounded, grounding-
type receptacle. Do not remove the third prong from the plug.
For maximum safety, this pump should be connected to a three-
prong grounded outlet equipped with a ground fault circuit inter-
rupter (GFCI) device.
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Pump should only be used with
liquids compatible with pump component materials. Do not use
in explosive atmospheres or hazardous locations as classified by
the NEC, ANSI/NFPA70. Failure to follow this warning can result
in property damage, personal injury, or death.
Do not handle a pump or pump motor with wet hands or when
standing on a wet or damp surface, or in water. Failure to follow
this warning can result in fatal electrical shock.
Make certain that the unit is disconnected from the power source
before attempting to service or remove any component. If the
power disconnect is out-of-sight, lock it in the open position and
tag it to prevent unexpected application of power.
Periodically inspect pump and system components. Regularly
check hoses for weakness or wear, making certain that all connec-
tions are secure. Perform routine maintenance as required and in
accordance with the Service Instructions section.
In any installations where property damage and/or personal injury
Model • Modèle • Modelo
VCC-20S
VCC-20ULS
CAREFULLY
BEFORE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
Figure 1.
might result from an inoperative or leaking pump due to power
outages, discharge line blockage, or any other reason, a backup
system(s) and/or alarm should be used.
Support pump and piping when assembling and when installed.
Failure to do so may cause piping to break, pump to fail, motor
bearing failures, etc.
DESCRIPTION
This Little Giant condensate pump automatically removes water
that drips from an air conditioner evaporative coil. The pump is
controlled by a float/switch mechanism, which turns on the pump
when approximately 1" of water collects in its tank, and turns off
the pump when the water in the tank drains to approximately
1/2".
INSTALLATION
1. Carefully unpack the pump. Remove the cardboard
packing from the motor cover air slots. Carefully slide the
packing away from the pump. This packing is used to prevent
switch movement during shipment.
2. Mounting the pump: The tank has two slots provided to mount
the unit (Figure 1). The slots are located on the end of the tank
cover. The unit should be mounted either on the side of the
air conditioner unit or nearby wall. Pump must be level and
the inlet must be below the coil drain. Conduit fittings are not
compatible with the plastic pump housing.
3. The pump should not be installed in a manner that will subject
it to splashing or spraying.
Figure 2.
Figure 3.
1

Publicité

loading

Sommaire des Matières pour Little Giant VCC-20S

  • Page 1 The Little Giant pump you have purchased is of the highest quality Support pump and piping when assembling and when installed. workmanship and material, and has been engineered to give you Failure to do so may cause piping to break, pump to fail, motor long and reliable service.
  • Page 2 1/2 po d’eau. 3. If debris collects in the check valve and prevents it from sealing Votre nouvelle pompe Little Giant a été fabriquée avec les meil- properly, the volume of water draining back into the tank from leurs matériaux et avec le plus grand soin. Elle a été conçue pour the 3/8"...
  • Page 3 3. Disjoncteur (Figures 2 et 3) : Le disjoncteur de débordement doit être connecté à un circuit à basse tension de catégorie II. FONCTIONNER OU D’ENTRETENIR LA POMPE LITTLE GIANT. IL FAUT CONNAÎTRE L’APPLICATION, LES LIMITESET LES L’assemblage typique de circuits ‘NC’ serait: DANGERS POTENTIELS DE LA POMPE.
  • Page 4 1/2". 3. La bomba no debería instalarse de tal forma que quede expu- La unidad Little Giant que usted ha adquirido posee la más alta esta a salpicaduras o rociaduras. calidad de fabricación y materiales. Ha sido diseñada para brindarle CONEXIONES ELECTRICAS una larga vida de servicio sin problemas.
  • Page 5 no es posible colocar en declive la tubería de descarga, haga 2. Quite la voluta y verifique que no haya obstrucciones. Limpie cuando sea necesario. un purgador en forma de “U” invertida, directamente sobre la bomba, en el punto más alto. 3.
  • Page 6 Item Part No. Description 154006 Cover, Motor • • • 154031 Fan • • • 979554 Motor, 115V • 979555 Motor, 230V • • 154021 Plate, Motor • • • 154055 Bracket, Switch • • • 950337 Switch, VC Pump •...
  • Page 7 Your Little Giant product is guaranteed to be in perfect condition la garantie. Little Giant va honorer la garantie dans la période de when it leaves our Factory. It is warranted against defective materials temps spécifiée.
  • Page 8 Para la Ayuda Técnica, por favor póngase en contacto ....1.888.956.0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 993554 - 06/2007 © 2007 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Ce manuel est également adapté pour:

Vcc-20uls