You can solve many common beverage center problems easily, saving you the cost of a possible
service call. Try the suggestions below to see if you can solve the problem before calling the servicer.
PROBLEM
Beverage center does
not operate.
Beverage center is not
cold enough.
The compressor turns
on and off frequently.
The light does not
work.
Vibrations.
The beverage center
seems to make too
much noise.
The door will not close
properly.
Turns on an off
frequently
Error Code:
E0-E1-E2

TROUBLESHOOTING GUIDE

POSSIBLE CAUSE
Not plugged in.
The appliance is turned off.
The circuit breaker tripped or a blown fuse.
External environment may require a higher
setting.
The door is opened too often.
The door is not closed completely.
The door gasket does not seal properly.
The room temperature is hotter than normal.
A large amount of contents has been added to
the unit.
The door is opened too often.
The door is not closed completely.
The temperature control is not set correctly.
The door gasket does not seal properly.
Not plugged in.
The circuit breaker tripped or a blown fuse.
The light button is "OFF".
The unit is not level.
The bottles are vibrating.
There is an object under the unit.
The unit is not level.
The unit is not level.
The door was reversed and not properly
installed.
The gasket is dirty.
The shelves are out of position.
The room temperature is hotter than normal. A
large amount of contents has been added tot he
appliance. The door is opened too often. The
door is not closed completely. The temperature
control is not set correctly. The door gasket
does not seal properly
A sensor has failed.
Plug the unit.
Press the power button to turn on the unit.
Check the breaker and/or fuses.
Check the temperature control setting.
Close the door properly.
Check the door gasket.
Close the door properly.
Check the door gasket.
Plug the unit.
Check the breaker and/or fuses.
Check to assure that the unit is level.
Make sure the bottles don't touch each other.
Remove the object.
Level the unit.
The rattling noise may come from the flow of
the refrigerant, which is normal. As each cycle
ends, you may hear gurgling sounds caused
by the flow of refrigerant in your unit.
Contraction and expansion of the inside walls
may cause popping and crackling noises.
Level the unit.
Close the door properly.
Clean the door gasket.
Place the shelves properly.
Check if the door is well close
Check if the gasket is ok.
Contact us for a service call.