Radiant Quattro SFK 57 Manuel D'installation Et De Maintenance page 48

Table des Matières

Publicité

PARAMÈTRE
P18
P19
P20
P21
P22
48
SFK 57 - RAD - FRA - Manuel Inst. - 2007.1_CSA
2. PREMIÈRE MISE EN ROUTE
DESCRIPTION
MINUTAGE POST-VENTILATION SUPPLEMENTAIRE
A TRAVERS CE PARAMETRE, IL VOUS SERA POSSIBLE D'Y
AJOUTER UN MINUTAGE SUPPLEMENTAIRE AUX 20 SECONDS
D'USINE POUR LE FONCTIONNEMENT DU VENTILATEUR APRES
L'ARRET DE L'APPAREIL.
PROTECTION DU COUP DE BELIER
SI CETTE FONCTION EST ACTIVEE, LE CONTACT SANITAIRE
SERA DEPLACE POUR UN MINUTAGE EGALE A LA VALEUR Y
REGLEE.
SELECTION DU PAYS DE DESTINATION
EN MODIFIANT CE PARAMETRE, LES PARAMETRES
DE CONTROLE DE LA COMBUSTION SONT ADAPTEES
AUTOMATIQUEMENT SELON LE PAYS DE DESTINATION DU
PRODUIT.
FONCTIONNEMENT DU CIRCULATEUR EN PHASE CHAUFFE-EAU
PAR L'AIDE DE CE PARAMETRE, IL EST POSSIBLE DE
CONNECTER/DECONNECTER LE CIRCULATEUR PENDANT LE
FONCTIONNEMENT DU CHAUFFE-EAU.
ACTIVATION DU PILOTAGE INDUSTRIEL DU BUS 0 -10V
AVEC CE PARAMÈTRE, IL EST POSSIBLE DE D'ACTIVER/
DÉSACTIVER L'ENTRÉE INDUSTRIELLE DU BUS 0-10 V POUR
RÉGLER À L'AIDE DU BUS EXTÉRIEUR LA PUISSANCE DU
BRÛLEUR OU LA TEMPÉRATURE DE SORTIE.
PLAGE
FONCTION
20 - 120
VALEUR EXPRIMÉE EN
SECONDES (RÉGLAGE EN
USINE SUR 30 SECONDES)
0 - 20
0 = DÉSACTIVÉ (RÉGLAGE
USINE SUR 0')
1-20 = VALEUR EXPRIMÉE EN
SECONDES
0 - 1
0 – ETATS UNIS / CANADA
1 – AUTRES PAYS
0 - 1
0 – DECONNECTE
1 - CONNECTION
0 - 2
0 = DÉSACTIVÉ
(ÉTABLI PAR DÉFAUT)
1 = MODE DE CONTRÔLE DE LA
TEMPÉRATURE
2 = MODE DE CONTRÔLE DE LA
PUISSANCE

Publicité