Technical Data - Buderus SU54/5 Notice D'installation Et D'entretien

Préparateur ecs
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2
Product Information
2.6

Technical Data

Tank capacity
Tank capacity (total)
Maximum flow rate
Maximum DHW temperature
Maximum operating pressure DHW
Standby heat loss (149 °F (65 °C) DHW temperature, 68 °F (20 °C) room
temperature)
DHW tank performance at:
Domestic cold water inlet temperature
Domestic hot water outlet temperature
DHW temperature rise
Heat exchanger supply temperature (heating water)
Flow rate (heating water)
Pressure drop (heating water)
Continuous rating
Amount that can be drawn off in the first hour
Maximum heat input
Heat exchanger
Content
Surface area
Maximum heating water temperature
Max. operating pressure, heat exchanger
Table 5 Technical Data
6
Unit
SU54/5
gal
51.3
(l)
(194)
gpm
5.1
(l/min)
(19)
°F
203
( °C)
(95)
psi
150
(bar)
(10.3)
°F/h
0.6
(K/h)
(0.33)
°F
50
( °C)
(10)
°F
140
( °C)
(60)
°F
90
( °C)
(50)
°F
176
( °C)
(80)
gpm
11.4
(l/h)
(2600)
foh
2.4
(mbar)
(72)
gph
130
(l/h)
(462)
gpm
2.00
(l/min)
(8.2)
gph
180
(l/h)
(680)
btu/hr
84 879
(kW)
(24.9)
gal
1.5
(l)
(5.7)
2
ft
9.69
2
(m
)
(0.9)
°F
230
( °C)
(110)
psi
232
(bar)
(16)
SU54.5 | SU80.5 | SU100.5 – 6 720 819 292 (2017/11)
SU80/5
SU100/5
77.4
98.4
(293)
(372)
7.7
9.8
(29)
(37)
203
203
(95)
(95)
150
150
(10.3)
(10.3)
0.5
0.4
(0.28)
(0.23)
50
50
(10)
(10)
140
140
(60)
(60)
90
90
(50)
(50)
176
176
(80)
(80)
11.4
14
(2600)
(3180)
2.7
3.8
(81)
(114)
189
218
(484)
(787)
2.10
3.05
(11.9)
(13.7)
264
312
(1000)
(1180)
119 217
143 872
(34.9)
(42.2)
2.3
3.1
(8.7)
(11.7)
13.99
19.38
(1.3)
(1.8)
230
230
(110)
(110)
232
232
(16)
(16)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Su80/5Su100/5

Table des Matières