2.
Conformity with standards
The explosionproof access points meet the
requirements of IEC 60079-0, IEC 60079-15 and
IEC 60079-31. They have been developed, man-
ufactured and tested in accordance with state-
of-the-art
engineering
9001:2015.
3.
Technical data
3.1
Marking
3.1.1 Areas with gas explosion hazard
II 3G
Ex nR IIC T6 Gc
3.1.2 Areas with dust explosion hazard
II 2D
Ex tb IIIC T80°C Db
3.2
Certification
3.2.1 EU type-examination certificate
BVS 20 ATEX E 103 X / BVS 20 ATEX E 105 X
3.2.2 IECEx Certificate
IECEx BVS 20.0081X / IECEx BVS 20.0083X
3.3
Enclosure ingress protection
Minimum degree of protection IP 66
3.4
Type code
SAnR 2 3 7 27 27 13
dimension
(length, height, depth [cm])
enclosure size 1 271 x 271 x 136 mm (standard)
enclosure size 2 542 x 271 x 136 mm (special version)
3.5
Electrical data
Rated voltage
Max. 60 V DC (see rating plate)
Conductor cross section CAT 7
3.6
Permissible ambient temperatures
The permissible ambient temperature is max.
–10°C to 60°C.
The data on the type plate are binding!