Exclude hot water tank (economy)
Hot water tank temperature maintaining/heating can
be excluded by the user. If excluded, domestic hot
water will not be delivered. The hot water tank can be
deactivated by the user (ECO mode) by pressing the
eco/comfort button (detail 10 - fig. 1). In ECO mode
the display activates the symbol
COMFORT mode, press the eco/comfort button (de-
tail 10 - fig. 1) again.
Information
From the main screen (Home), press the contextual button 2 (detail 2 - fig. 1). Then use the "Menu Navigation" buttons
to display the following values:
1
Heating demand
2
Heating circulating pump
3
Heating 3-way valve
4
DHW 3-way valve
5
Standby time
6
T Delta protection
7
Flame Supervisor
8
Heating sensor 1 (Flow)
9
Heating sensor 2 (Safety)
10
Return sensor
11
DHW sensor
12
External probe
13
Fume sensor
14
Cascade heating sensor
15
Fan frequency
16
Burner load
17
System water pressure
18
Modulating circulating pump
19
Cascade modulating circulating pump
20
Ionization current
21
Input 0-10Vdc
22
Heating adjustment temperature
23
Power level adjustment 0-10Vdc
220
. To activate
OT - OpenTherm control request
TA - Room thermostat request
0-10Vdc - 0-10Vdc signal request
TA2 - Second room thermostat request
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
°C
°C
°C
°C
°C
°C
°C
Hz
%
1.4bar = ON, 0.0 bar = OFF
%
%
uA
Vdc
Setpoint (°C)
Setpoint (%)
cod. 3541V233 - Rev 00 - 06/2022
FORCE W
23°C
32°C

Thursday 9 Jan. 2014 11:30:43

fig. 7- Economy