Installing the Insert
!
: This also pertains to vertical vent systems installed
on the outside of the building.
ROOF PITCH
Flat to 6/12
6/12 to 7/12
Over 7/12 to 8/12
Over 8/12 to 9/12
Over 9/12 to 10/12
Over 10/12 to 11/12
Over 11/12 to 12/12
Over 12/12 to 14/12
Over 14/12 to 16/12
Over 16/12 to 18/12
Over 18/12 to 20/12
Over 20/12 to 21/12
Figure 2. Minimum Height from Roof to Lowest
Discharge Opening
(continued)
2 FT
(61cm)
MIN.
D'ÉCHAPPEMENT
TERMINATION
CAP
(MITRE)
H (MIN.) FT.
1.0
1.25
1.5
2.0
2.5
3.25
4.0
5.0
6.0
7.0
7.5
8.0
Installation
!
systèmes de ventilation installés à l’extérieur d’un
bâtiment.
HORIZONTAL OVERHANG
2 FT (61cm)
MIN.
LOWEST
DISCHARGE
OPENING
(ORIFICE
LE PLUS BAS)
X
12
ROOF PITCH IS X/ 12
(PENTE DU TOIT X/12)
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
(H (MIN) - HAUTEUR MINIMUM DU TOIT
À L'ORIFICE D'ÉCHAPPEMENT LE PLUS BAS)
Pente du toit
plat à 6/12
de 6/12 à 7/12
de 7/12 à 8/12
de 8/12 à 9/12
de 9/12 à 10/12
de 10/12 à 11/12
de 11/12 à 12/12
de 12/12 à 14/12
de 14/12 à 16/12
de 16/12 à 18/12
de 18/12 à 20/12
de 20/12 à 21/12
Figure 2. Hauteur minimum du toit à l’orifice
d’échappement le plus bas
14
(suite)
Ces dimensions s’appliquent aussi aux
(SURPLOMB)
VERTICAL WALL
(MUR VERTICAL)
H (min.) cm
30,5 cm
38 cm
45,75 cm
61 cm
76,25 cm
99 cm
122 cm
152,5 cm
183 cm
213,5 cm
228,75 cm
244 cm