Charge the battery pack only with the charger provided.
Allow at least 90 minutes of charge time for 2.5Ah battery,
140 minutes of charge time for 4Ah battery, or 180 minutes of
charge time for 5Ah battery before initial use of the blower.
Make sure the power supply is normal household voltage,
120 volts, 60Hz, AC only.
The battery charger should be operated in temperatures
between
39 and 104 degrees F.
The battery should be charged in a cool, dry place.
2 to 3 initial charging/discharging cycles may be required to
achieve maximum run time/capacity.
DO NOT attempt to open the charger or the unit. There are
no customer serviceable parts inside. Call customer service
helpline at
1-800-618-7474 for
DO NOT incinerate battery packs even if they are severely
damaged or completely worn out. They can explode in a fire
causing injury.
DO NOT charge appliance in rain, or in wet locations.
Use the battery charger indoors only.
Disconnect charger from the power supply when not in use to
prevent damage to the charger during a power surge.
TO CHARGE - SEE CHARGER MANUAL FOR COMPLETE INSTRUCTIONS
Battery
Pack
BATTERY DISPOSAL
Remove the battery pack from the tool, cover the terminals with heavy duty adhesive tape. Do not attempt to destroy or
disassemble battery pack or remove any components. This product contains lithium-ion batteries which must be recycled or
disposed of properly. Local, state or federal laws may prohibit disposal of these batteries in the municipal solid waste or rural
trash pick up systems.
The RBRC seal on the Li-Ion battery pack indicates that the cost to recycle the battery pack at the end of its
useful life has already been paid by The Great States Corporation/American Lawn Mower Company. It is illegal
to place spent Li-Ion batteries in the local municipal solid waste or in the trash. RBRC in cooperation with The
Great States Corporation/American Lawn Mower Company has provided an environmentally friendly and easy
way to recycle spent Li-Ion batteries. Just contact your local recycling center or call 1.800.8.BATTERY for
information on where to drop off the spent battery.
CHARGING THE BATTERY PACK
assistance.
Charger
Model LB20062S
When fully charged, the battery can be safely stored in
temperatures down to -4 degrees F for a period of up to four
weeks, before requiring charging. Fully charge battery pack
every 90 days.
If over a period of time the battery pack quickly runs down
after a full
90, 140 or 180 minutes
replacement battery pack is needed.
To prevent permanent damage to the battery, never store in
a discharged condition.
WINTER STORAGE - Fully recharge before storage and
then again every 90 days.
Since the battery will not develop a memory, it does not
have to be fully discharged before recharging.
A small leakage of liquid from the battery cells may occur
under extreme usage, charging or temperature conditions.
This does not indicate a failure. However, if the outer seal is
broken and this leakage gets on your skin.
a.
Wash quickly with soap and water.
b.
Neutralize with a mild acid such as lemon juice or
vinegar.
c.
If the battery liquid gets in your eyes, flush them with
clean water for a minimum of 10 minutes and seek
immediate medical attention.
Constant Red + Flash Green = Battery is charging
Constant Red + Constant Green = Battery is fully charged
5