Télécharger Imprimer la page
Campbell Hausfeld PA208501 Instructions D'utilisation Et Manuel De Pièces
Campbell Hausfeld PA208501 Instructions D'utilisation Et Manuel De Pièces

Campbell Hausfeld PA208501 Instructions D'utilisation Et Manuel De Pièces

Nettoyeur / sécheur à air

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and
others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for
future reference.
Description
The Campbell Hausfeld Air Cleaner /
Dryer is designed to remove dirt, most
contaminants, oil and water from
compressed air. It is a two part system
consisting of a coalescing filter which
removes most contaminants, oils and
condensed water and a desiccant dryer
which removes water vapor.
Unpacking
After unpacking the air cleaner / dryer,
carefully inspect for any damage that
may have occurred during transit.
Check for loose, missing or damaged
parts.
Safety Guidelines
This manual contains information that is
very important to know and
understand. This information is provided
for SAFETY and to
PREVENT EQUIPMENT PROBLEMS. To
help recognize this information, observe
the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
General Safety
Information
This product is a part of a high pressure
system and the following safety
precautions must be followed at all
times along with any other existing
safety rules.
© 1999 Campbell Hausfeld/Scott Fetzer
Air Cleaner / Dryer
1. Read this instruction
manual before installing
this device on a
compressed air system.
Be thoroughly familiar
with the controls and
the proper use of the equipment.
2. Safety glasses must be worn during
operation. Always work in a well
ventilated area.
3. Do not exceed any pressure rating of
any component in the system.
4. Protect air lines from damage and
puncture.
5. Check air hoses for weak or worn
condition before each use. Make
sure all connections are secure.
6. Keep all nuts, bolts and screws tight
and ensure equipment is in safe
working condition.
This product is
specifically
designed for compressed air service
ONLY. Use with any other fluid (liquid
or gas) is a misapplication and not
permitted. For example, use with or
injection of certain hazardous liquids
or gases in the system (such as alcohol
or liquid petroleum gas) could be
harmful to the unit or result in a
combustable condition or hazardous
external leakage. Campbell Hausfeld's
warranties are void in the event of
misapplication and assumes no
responsibility for any resulting loss.
Specifications
Maximum pressure: 150 PSIG (10 bar).
Maximum temperature: 125˚F (52˚C).
Installation
Disconnect power
and release all
pressure from the system before
attempting to install, service, relocate
or perform any maintenance.
1. The air cleaner/dryer should be
located as close as possible to the air
tool or spray gun.
2. A shutoff valve should be installed
before the air cleaner/dryer so the
unit can be easily depressurized for
servicing. Securely mount the air
cleaner/dryer in a vertical position
using the mounting bracket supplied
with the unit.
For parts, product & service information
visit www.campbellhausfeld.com
Model PA208501
Service
Indicator
MANUAL
Coalescing
Filter
Figure 1
3. Install a Campbell Hausfeld 3/8"
Filter (PA2121) before and after the
coalescing filter/dryer for optimum
performance. Connect the piping or
hose with airflow in the direction of
the arrows cast into the top of the
unit. Avoid using unnecessary
fittings, couplings, etc., that restrict
air flow.
4. Remove the bowl from the dryer
housing by pushing the bowl toward
the body and rotating bowl. Pull
bowl down to remove from housing.
5. Open bag of desiccant and pour into
bowl. Shake or tap bowl periodically
to settle desiccant. Fill to within 1/2"
from top of bowl. Do not allow
desiccant to get into center tube.
6. Reinstall bowl on housing. Be sure it
is securely locked in place before
pressurizing the unit.
7. The coalescing filter is supplied with
the filter element preinstalled.
8. Be sure to use a clean air hose to
prevent contamination of the
cleaned air.
9. Pressurize system and check for any
air leaks.
Operation
Before turning on the air pressure
supply, make certain the bowls are
securely locked in place and all fittings
are tight.
Mounting Bracket
Dryer
IN245501AV 5/99

Publicité

loading

Sommaire des Matières pour Campbell Hausfeld PA208501

  • Page 1 Service Mounting Bracket manual before installing Indicator this device on a MANUAL The Campbell Hausfeld Air Cleaner / compressed air system. Dryer is designed to remove dirt, most Be thoroughly familiar contaminants, oil and water from with the controls and compressed air.
  • Page 2 WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld product. WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: Any Campbell Hausfeld nailer, stapler, air tool, spray gun, inflator or air accessory supplied or manufactured by Warrantor.
  • Page 3 Air Cleaner / Dryer Model PA208501 Serious and extreme Duty Units Do not disassemble The bowl on this Certain compressor bowl from guard unit is made with oils, chemicals, for any reason other than parts polycarbonate plastic. Do not allow household cleaners, solvents, paints replacement.
  • Page 4 Filtre de 9,5 mm (PA2121) indique une situation liquides ou gaz hasardeux dans le Campbell Hausfeld en position avant système (tels que l’alcool ou le gaz de hasardeuse potentielle qui, si pas évitée, et après le filtre/sécheur. Brancher les pourrait résulter en perte de vie ou blessures...
  • Page 5 Modéle PA208501 Nettoyeur / Sécheur à Air en tournant au sens contraire des 2. Remplacer le siccatif lorsqu’il devient Montage (Suite) aiguilles d’une montre. Tirer le bol rose et remplacer la cartouche en bas pour l’enlever du carter. filtrante lorsque l’indicateur de 6.
  • Page 6 8. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. Livraison ou expédition du produit ou de la pièce Campbell Hausfeld au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Page 7 Modéle PA208501 Nettoyeur / Sécheur à Air Modèles À Service Sérieux et extrême Ne pas démonter le Le bol sur ce Certains huiles, bol du protecteur modèle est produits chimiques, de bol pour autres raisons que le fabriqué d’un plastique polycarbonate.
  • Page 8 PODRiA ocasionarle la muerte o peligrosas. en caso del uso inadecuado 3. Instale un filtro Campbell Hausfeld heridas de gravedad. las garantías otorgadas por la Campbell (PA2121) de 9,5mm (3/8”) antes y Hausfeld quedarían anuladas y la Ésto le indica que...
  • Page 9 Modelo PA208501 Purificador de Aire / Secador la presión del sistema sea de 0,69 bar elemento del filtro. Use el elemento Instalación (Cont.) (10 osig) o inferior. de filtro PA2087. 2. Los únicos servicios adicionales a. Cierre el flujo de aire hacia el...
  • Page 10 A. La reparación o reemplazo dependerá del flujo normal de trabajo del centro de servicio y de la disponibilidad de repuestos. B. Si el comprador no recibe resultados satisfactorios en el Centro de Servicio a Clientes de Campbell Hausfeld. (Vea el Párrafo 2).
  • Page 11 Modelo PA208501 Purificador de Aire / Secador Modelos resistentes y Modelos robustos el envase de esta No desconecte el Algunos aceites unidad está hecho envase del filtro para compresores, de plástico policarbonato. No permita de la cubierta a menos que necesite químicos, productos para limpieza...
  • Page 12 Air Cleaner / Dryer Model PA208501 Nettoyeur / Sécheur à Air Modéle PA208501 Purificador de Aire / Secador Modelo PA208501 For Replacement Parts, Call 1-800-543-6400 Please provide following information: Address parts correspondence to: -Model number The Campbell Group/Attn: Parts Dept.