Télécharger Imprimer la page

Faber CLASSICA Mode D'emploi page 5

Publicité

Les langues disponibles

Les langues disponibles

CAUTION
To reduce risk of fire and to properly exhaust
air, be sure to duct the air outside – Do not vent
exhaust air into spaces within walls or ceilings
or into attics, crawl spaces, or garages.
TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
WARNING
!
PERSONAL INJURY HAZARD
Because of the weight and size of the
rangehood canopy, two or more people
are needed to move and safely install the
rangehood canopy.
Failure to properly lift rangehood could
result in damage to the product or personal
injury.
PLAN THE INSTALLATION
This rangehood can be installed as either ducted or ductless. In a ducted
application, this rangehood can be vented through the wall or ceiling. To vent
through a wall, a 90° elbow is used. When installed ductless, the rangehood
vents out of the grates on the sides of the lower chimney. Ductless installations
require a Ductless Conversion Kit, available from your dealer.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION,
DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY
CALCULATE ALL MEASUREMENTS.
RANGEHOOD COMPONENTS
A. CANOPY SECTION
B. LOWER CHIMNEY COVER
C. UPPER CHIMNEY COVER
D. MOUNTING SCREWS
E. CHIMNEY MOUNTING BRACKETS
F. CHIMNEY SCREWS
G. DAMPER
G
A
CALCULATE THE DUCTRUN LENGTH
To ensure that the blower performs to its highest
possible capacity, duct work should be as short
and straight as possilbe.
For satisfactory performance the duct run should
not exceed 50 equivalent feet if ducted using the
required minimum 6" round duct. Calculate the
length of the ductwork by adding the equivalent
feet in FIGURE 2 for each piece of duct in the
system An example is given in FIGURE 3.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
as possible.
E
C
B
FIGURE 1
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 2
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
FIGURE 3
Version 09/12- Page 5
F
D
3.0 feet
5.0 feet
12.0 feet
0.0 feet
9.0 feet
10.0 feet
0.0 feet
19.0 feet

Publicité

loading

Ce manuel est également adapté pour:

Clas36ss