INSTALLATION
SAFE WEIGHT
The weight of an INVIKTUS safe is related to its size; it is indicated on the label plate located on
the door back plate. It is the customer's responsibility to check that his floor will be able to stand
the floor load.
Moreover, the EN1143-1 specifies that safes which weighs under 1000kgs (2205 lbs) MUST be
fixed. If you have purchased an INVIKTUS 14, 20 or 30 in any of the grades III or IV, the weight
of your safe is below 1000kgs (2205 lbs) and must therefore be fixed.
SAFE FIXING
All INVIKTUS safes are prepared to be based fixed (5 possibe fixing holes) or wall fixed (1 back
fixing hole).
Models 14, 20 and 30 grade III and IV are delivered with one anchoring kit included (M16 bolt and
washer).
For all others sizes, a fixing kit is available as an option.
RECOMMENDATIONS PRIOR TO FIXING
We would draw your attention to the fact that only a solid concrete support with high compression
strength (> 250 bar/25MPa/3626 PSA) and at least 150 mm (5,9 in) thick allows correct fixing.
Moreover, if the safe is backed against a wall, the clearance between the wall and the safe must
be kept to a minimum.
If the safe is raised on a plinth, it can be screwed on the floor using the extension kit (available as
an option)
FIXING METHOD
 Drill the floor with a 24 mm diameter hole, with a minimum of 105mm depth
 Position your safe so that the fixing hole matches the floor hole
 (If necessary insert the extension kit)
 Insert the washer and the bolt and screw up with a dynamometer screw-driver until you reach
a torque comprised between 120N.m (88 ft.lb) and 200N.m (148 ft.lb)