Télécharger Imprimer la page

JB Systems FX 700 Mode D'emploi page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
ENGLISH
OPERATING INSTRUCTIONS
 Put the fogger on a flat and very stable surface. Make sure that nobody can put their hands just in front of
the output. The fog is very hot and can cause serious burnings!!!
 Make sure the fog liquid tank is not empty. Always use good quality fog liquid to fill up the tank. Close the
tank immediately to prevent dirt to enter the reservoir!
 Plug the supplied remote in the "remote control" input (5) on the back of the unit. Don't insert or remove
the remote while the fogger is connected to the mains!
 Make sure to plug the fogger in a mains wall socket with earth connection
 Switch the fogger on and wait for about 5 minutes. (warm up time)
Used with the supplied remote controller:
1. REMOTE CABLE: connect the special 3pin connector to the remote
input on the back of the fogger (5).
2. MANUAL FOGGING BUTTON: for as long as the green LED is on, you
can press this button at any time to produce fog. (regardless of the
operation mode selected with the timer on/off button [8])
3. WARMING UP INDICATOR: indicator is lit while the fogger is warming
up. The fogger is ready to fog when the indicator is off.
Used with the optional wireless FC5 controller:
 Connect the special 3pin connector (1) to the remote input on
the back of the fogger.
 Fix the remote receiver (2) with its magnetic surface to the back
of the fogger.
 When the fogger is ready for operation, the green LED (3) turns
off.
 The fogger produces fog as long as you press the button (4) on
the wireless remote. (after some time the green LED on the
receiver will turn on to indicate that the fogger is warming up
again, during this time you can't produce any fog)
 Don't forget to pull out the antenna (5) on the transmitter to
obtain the maximum working distance.
Remark: the maximum distance between the wireless remote and the fogger is about 50m.
MAINTENANCE
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
Cleaning the fogger:
To prevent obstructions in the heater, pump and tubes, the fogger should be cleaned on a regular basis:
every 100h of continuous operation is a good reference.
 Switch the fogger off
 Remove the nozzle (metal part where the fog leaves the fogger)
 Remove the fog liquid from the tank
 Fill the tank with about 1liter of a solution containing 80% distilled water and 20% white vinegar.
 Switch the fogger on and wait for about 8minutes (warm up time)
 Put the fogger in continuous operation mode until the tank is empty
 Put the nozzle back in place
 Remove the eventual residues of the cleaning solution and refill the tank with fog liquid.
Remark: cleaning should be done outside; an awful smell is produced by the vinegar solution!
JB SYSTEMS
®
OPERATION MANUAL
3/24
FX-700 FOGGER
ENGLISH
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 230V, 50Hz
Power consumption:
700 Watt
Fuse (size: 5x20mm):
3,15A
Output:
2500 cubic ft/min
Warm up time:
5 min
Tank size:
0,8L
Size:
330 x 160 x 130 mm
Weight:
3,6 kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS
®
OPERATION MANUAL
4/24
FX-700 FOGGER

Publicité

loading

Ce manuel est également adapté pour:

Fx-700