SET UP

Place the laser on a flat surface or on tripod. Press KEY 1 to
switch the instrument on. The laser will level and LED 1 will
flash green. When the laser is leveled, LED 1 will glow contin-
uous green and the laser will begin to rotate. The laser is now
ready for use.

SETTING A GRADE

After setting, press KEY 4, LED 4 will be green. A slope in the
X-axis can now be set. The Y-axis will remain level in this
position. Also, the TILT function will continue to operate on the
Y-axis. With KEY 5 & 6 you can now set a slope up or down on
the X-axis.
Press KEY 4 again to set a grade on the Y axis, LED 4 will be
red. The X-axis will remain level in this position. Also, the TILT
function will continue to operate on the X-axis. With KEY 5 & 6
you can now set a slope up or down on the Y-axis.

USE OF THE MANUAL MODE

Press KEYN 3 to activate manual mode. LED 3 will light up red.
The laser is no longer self-leveling. When the manual mode
is switched on, the laser can be set at an arbitrary angle of up
to 50°.

TILT FUNCTION

After about 30 seconds, the TILT function will be turned on
automatically. TILT LED 2 will then light up green. In the event
of a shock or severe vibration affecting the accuracy of the
laser, the laser will stop and the TILT LED (2) will flash green.
You can start the laser again by pressing the TILT KEY (2). In
this case, you should check whether the laser is still set to
the correct level.

CHECKING THE ACCURACY

IMPORTANT!!!
Always check accuracy before starting work!
LEVELFIX is not responsible for any damage caused by the use
of this laser. You are responsible for the use and accuracy of
the instrument at all times.
1.
Place the 860H on a flat, level surface or tripod approxi-
mately 100 feet (30 meters) from a wall.
2.
Align the first axis so that it is perpendicular to the wall.
Let the 860H level itself fully automatically.
3.
Mark the position of the beam (X+).
4.
Rotate the laser 180° and let the laser level itself againy.
5.
Mark the opposite side of the first axis (X-)
6.
Align the second axis of the 860H by turning it 90° so
that it is perpendicular to the wall. Let the laser level
itself again.
7.
Mark the position of the beam (Y+).
8.
Rotate the laser 180° and let the laser level itself again.
9.
Mark the opposite side of the first axis (Y-)
The 860 is within spec if the maximum distance
between the 4 marks is less than 3mm.
If the distance is greater than 3 mm, the laser must be
calibrated.
Please contact your dealer or a LEVELFIX authorized ser-
vice center for this.