1
STEP MOTOR / REGULATOR
1
#53 BURNER ORIFICE
1
#53 BURNER ORIFICE
1
CONVERSION DATA LABEL
1
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible
for the proper installation of this kit. The installation is not proper and complete until the operation
of the converted appliance is checked as specified in the owner instructions supplied with the kit.
WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this
appliance may result in property damage or personal injury.
CAUTION: Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.
1. Remove the door and log set or glass from the fireplace. Refer to the "FINISHING" section of your installation manual for instructions.
2. Logs Only: Remove the center log support bracket (4 screws). Then remove the four tube burner cap brackets (8 screws).
2. Glass/Rock Only: Remove the porcelain base (4 screws). Then remove the burner assembly (4 screws). (Carefully, not to damage the
pilot line)
3. Remove the tube burner(s).
4. Using a deep socket wrench, remove both orifices. A back-up wrench must be used on the manifold to ensure that the tubing does
not twist or kink. Using pipe thread compound, replace with the orifices supplied.
5. Before replacing the burners, adjust the air shutters according to the table located on the back of this page.
LOG BURNER
CENTER LOG
SUPPORT BRACKET
GLASS BURNER
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada
FUEL CONVERSION KITS FOR BURNERS
B81L
PILOT INJECTOR
CAP
BRACKETS
SCREWS
PORCELAIN
BASE
B81L, B81G, B81S
B81G/B81S
W175-0313 NG TO P
STEP MOTOR / REGULATOR
#52 Outer Ring BURNER ORIFICE
#54 Inner Tube BURNER ORIFICE
CONVERSION DATA LABEL
PILOT INJECTOR
ROCK BURNER
GLASS/ROCK BURNER
ORIFICES
BURNER TUBE
• (705)721-1212
B81L/B81G/B81S
W175-0312 P TO NG
STEP MOTOR / REGULATOR
#34 BURNER ORIFICE
#34 BURNER ORIFICE
CONVERSION DATA LABEL
PILOT INJECTOR
BURNER ASSEMBLY
#52
ORIFICES
Continued on reverse
• fax (705)720-9081
• www.napoleonfireplaces.com
PORCELAIN
BASE
#54
W415-0956 / A / 12.09.16

Publicité

loading

Sommaire des Matières pour Napoleon B81L

  • Page 1 SUPPORT BRACKET GLASS/ROCK BURNER ORIFICES BURNER ASSEMBLY GLASS BURNER SCREWS BURNER TUBE ORIFICES PORCELAIN BASE Continued on reverse W415-0956 / A / 12.09.16 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • fax (705)720-9081 • www.napoleonfireplaces.com...
  • Page 2 FIRMLY TO SEAL. DO NOT OVER TORQUE. LEAK TEST Maximum Input Ratings: 60,000 BTU/hr 50,000 BTU/hr PILOT SCREW W415-0956 / A / 12.09.16 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • fax (705)720-9081 • www.napoleonfireplaces.com...
  • Page 3 ASSEMBLAGE DU BRÛLEUR BRÛLEUR POUR LES BRAISES VITRIFIÉES TUBE DU BRÛLEUR INJECTEURS BASE EN PORCELAINE Suite au verso W415-0956 / A / 12.09.16 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • télécopieur(705)720-9081 • www.napoleonfoyers.com...
  • Page 4 LES VIS POUR SCELLER. NE SERREZ PAS TROP FORT. Débit maximal: VÉRIFIEZ POUR DES FUITES 60,000 BTU/h 50,000 BTU/h VIS DE LA VEILLEUSE PILOT SCREW W415-0956 / A / 12.09.16 Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada • (705)721-1212 • télécopieur(705)720-9081 • www.napoleonfoyers.com...

Ce manuel est également adapté pour:

B81gB81s