Maintenance

7
Maintenance
7.1

Maintenance work

Proper operation of the Wöhler RP 72 Soot Test
Pump requires regular maintenance. .
Interval
After each working day
Regularly
Twice a year
Maintenance work
Airing and drying of
the soot test pump:
Take out plug (6) and
(24).
Exchange wet cot-
tonwool filter rolls
(12)
Open the measuring
heads (1) and (4).
Clean the measuring
probe with the probe
cleaning brush (see
accessories).
Greasing the sleeve
(21)
Loosen the screws
(8) and take off the
piston guide (18).
Pull out piston (20)
and sleeve (21).
Clean sleeve (4) and
pump pipe (9) with a
soft cloth from the in-
side, put piston 20
with sleeve (21) back
into the pipe and
squirt a little special
maintenance lubri-
cant on the back of
the sleeve.
Check the accuracy of
the Soot Test Pumpe
EN