1. DESCRIPTION
The detector registers movement via a passive infrared sensor (PIR). It is most sensitive to turning movements
within the controlled detection range (see Fig. 1a). The sensitivity to movements directly towards the sensor is
about 50% less (see Fig. 1b).
The detector comes in the following 8 versions:
Colour
351-03140
White
351-03145
Black
351-03150
Alu
351-03155
Brown
351-03160
White
351-03165
Black
351-03170
Alu
351-03175
Brown
2. USE
The detector is suitable for controlling indoor lighting or the lighting in a protected outdoor environment. Be
aware of the following during installation:
• Only mount the detector on stable walls.
• Hide any moving objects within the controlled detection range by shielding the lens.
• Do not place any lighting underneath or closer than 1 m from the detector (see Fig. 2a).
• Do not mount the detector in the direct path of a cold or hot air flow (see Fig. 2a and Fig. 2c).
3. MOUNTING
The detector is designed for mounting on the wall at a height of 2 to 4 m. The range of the detection area
depends on the mounting height (see Fig. 1c).
The detector is mounted as follows:
1. Carefully unscrew the detector from its base (see Fig. 4a)
2. Mark the place for the drill holes on the wall and drill them.
3. Pull the wire through the flexible membrane input (see Fig. 4b).
4. Fix the detector using screws and plugs (see Fig. 4c).
5. Connect the detector as shown in the wiring diagram in Fig. 7.
6. Place the detector back onto the base.
4. WIRING
Connect the detector as shown in the wiring diagram in Fig. 7.
The circuit must be protected with a fuse.
Conductor
Neutral conductor
Switched output relay
5. CONNECTING DEVICES
A high inrush current decreases the life span of the relay integrated into the detector. Respect the technical
specifications of the lighting manufacturers to prevent overloading the relay. We recommend connecting a
maximum of 3 to 4 detectors in parallel. This keeps the switching circuit organised. If the number of switching
cycles is higher than average or in case of an increased load, we recommend to run the load via an external
relay or an external fuse.
6. CONFIGURATION
The detector is ready for use approximately 1 minute after connection to the electricity grid. The settings can only
be changed while the detector is switched on. The following settings can be changed using the potentiometer
on the device:
6.1. Switch-off delay
Using the TIME potentiometer, the switch-off delay after the final movement is set (see Fig. 6a).
6.2. Light sensitivity
Using the LUX potentiometer, you can set the threshold value of the twilight switch continuously between ð(day
mode, 1000 lux) and ƒ (night mode, 5 lux) (see Fig. 6b).
6.3. Adjusting the detection range
You can reduce the detection area by cutting the supplied cover to size and fitting it to the detector head (see
Fig. 7). Alternatively, you can also cover certain parts of the lens with adhesive tape.
You can optimise the detection range by directing the detector. You can turn the director 45° downwards and
45° to the left or right (see Fig. 6c).
7. DISPLAY
The indication LED on the device indicates when a movement has been registered. During the start-up the LED
will keep flashing (approx. 1 min.).
8. TROUBLESHOOTING
4
Malfunction
Solution
The switch output does
• The twilight level has been set too high. Lower light sensitivity.
not switch.
• Check the lighting and the fuse.
• Direct the detector better.
The switch output
• Decrease the detection range.
switches too often.
• Direct the detector better.
EN
nv Niko sa Industriepark West 40, BE-9100 Sint-Niklaas, Belgium — tel. +32 3 778 90 00 — fax +32 3 777 71 20 — e-mail: support@niko.be — www.niko.eu
Detection angle
140°
200°
L
N
L'
9. TECHNICAL DATA
Dimensions (H x W x D)
Power supply voltage
Maximum incandescent lamp load
Maximum load for 230 V halogen lamps
Maximum load for low voltage halogen lamps
Maximum load for (non-compensated)
fluorescent lamps
Maximum load for economy lamps (CFLi)
Maximum load for 230 V LED lamps
Detection angle
Detection range at a height of 3 m
Mounting height
Light sensitivity
Switch-off delay
Protection class
Protection degree
Temperature range
10. WARNINGS REGARDING INSTALLATION
• The installation should be carried out by a registered installer and in compliance with the statutory regulations.
• This user manual should be presented to the user. It should be included in the electrical installation file,
and it should be passed on to any new owners. Additional copies are available on the Niko website or via
the Niko support service.
• During installation, the following should be taken into account (non-exhaustive list):
- the statutory laws, standards and regulations.
- the technology currently available at the time of installation.
- this user manual, which only states general regulations and should therefore be read within the scope
of each specific installation.
- the rules of proper workmanship.
This product complies with all of the relevant European guidelines and regulations. If applicable, you can find
the EU declaration of conformity regarding this product at www.niko.eu.
11. NIKO SUPPORT
In case of doubt or for the specific exchange procedure in case of a possible defect, contact the Niko support
service in Belgium at +32 3 778 90 80 or your wholesaler/installer. Contact details and more information can
be found at www.niko.eu under the "Help and advice" section.
12. GUARANTEE PROVISIONS
• The period of guarantee is four years from the date of delivery. The delivery date is the invoice date of
purchase of the product by the consumer. If there is no invoice, the date of production applies.
• The consumer is obliged to inform Niko in writing about the non-conformity, within two months after
stating the defect.
• In case of a non-conformity, the consumer only has the right to a product repair or replacement free of
charge, which shall be decided by Niko.
• Niko shall not be held liable for a defect or damage resulting from incorrect installation, improper or careless
use, incorrect operation, transformation of the product, maintenance that does not adhere to the maintenance
instructions or an external cause, such as damage due to moisture or overvoltage.
• The compulsory regulations of the national legislation concerning the sale of consumer goods and the
protection of the consumer in the countries where Niko sells, directly or via sister companies, subsidiaries,
chain stores, distributors, agents or permanent sales representatives, take priority over the above-mentioned
rules and regulations.
Do not dump this product with the unsorted waste. Bring it to a recognised waste collection point. Together with producers
and importers, you have an important role to play in the advancement of sorting, recycling and reusing discarded electrical
and electronic appliances. In order to finance the waste collection and processing, the government levies a recycling
contribution in some cases (included in the purchase price of this product).
351-0314x
351-0315x
351-0316x
100 x 70 x 100 mm
230 V / 50 Hz
1000 W
1000 W
500 VA
500 VA
100 W
100 W
140°
140°
200°
approx. 11 m in front and approx. 5.5 m to the sides
approx. 2 – 4 m
5 – 1000 lux
Pulse (approx. 1 s), approx. 30 s to 15 min.
Class II
IP44
-20 to +55 °C
PM351-03140R16244
351-0317x
200°

Publicité