Télécharger Imprimer la page

Monacor MAESTRO-1 Manuel D'utilisation page 5

Publicité

Les langues disponibles

Les langues disponibles

6.7 MESSAGES - INPUT CONTACTS
A message can be triggered for each input contact of the Maestro.
For input contact 1, the file held in the «Message 1» folder will be broadcast.
• 210;TYPE_I1;0;
By default, input contact 1 is normally open, in pulse mode (0). In this case, a short closing of the contact triggers the
broadcast of the message held in the «Message 1» folder.
Input contact 1 can be normally closed, in pulse mode (1). In this case, a short opening of the contact triggers the broad-
cast of the message held in the «Message 1» folder.
Input contact 1 can be normally open, in permanent mode (2). In this case, the message starts to broadcast as soon as the
contact is closed and it will continue as long as the contact remains closed or until the end of the audio file.
Input contact 1 can be normally closed, in permanent mode (3). In this case, the message starts to broadcast as soon as
the contact is open and it will continue as long as the contact remains open or until the end of the audio file.
• 211;NB_BROADCAST_I1;1;
This parameter defines the number of broadcasts for the file held in the «Message 1» folder. The default value is (1).
It is possible to increase this value in order to broadcast this message several times in a row, the maximal value is 255.
• 212;INTERVAL_BROADCAST_I1;0;
If the number of broadcasts is higher than 1, this parameter defines the interval in seconds between each broadcast.
The default value is (0)s and there is no interval between broadcasts. The maximal value is 3600s (i.e. 1h).
• 213;PRIORITY_I1;1;
By default, «Message 1» has a priority level of (1).
The value 0 corresponds to the maximal priority and 99 to the minimal priority.
214;VOLUME_I1;0;
«Message 1» has a volume (0) by default. Value 0 is for the maximal volume and 80 for the minimal volume.
The audio output can also be tuned using the volume button (MES.) from the front panel.
215;RELAY_I1;1;
By default, output relay R1 is activated (1) during the broadcast of «Message 1».
It is possible to activate relay R2 (2) or both relays R1 and R2 (3). Relays can also be deactivated (0).
In a similar way, there are parameters for the messages triggered by input 2 to input 6 :
• 220;TYPE_I2;0;
• 221;NBRE_DIFF_I2;1;
• ...
• ...
260;TYPE_I6;0;
261;NB_BROADCAST_I6;1;
• 262;INTERVAL_BROADCAST_I6;0;
263;PRIORITY_I6;6;
• 264;VOLUME_I6;0;
• 265;RELAY_I6;1;
Default values for the various parameters are identical for all messages, except for priority.
The priority levels for input contacts are set to the values 1 to 6.
• 213;PRIORITY_I1;1;
223;PRIORITY_I2;2;
• 233;PRIORITY_I3;3;
• 243;PRIORITY_I4;4;
• 253;PRIORITY_I5;5;
• 263;PRIORITY_I6;6;
Each message has a priority level, by default.
The value 0 corresponds to the maximal priority and 99 to the minimal priority.