Télécharger Imprimer la page

Axis T8085 PS57 500W 1U Guide D'installation page 11

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Output voltage
57 V DC
Output current
Max. 8.80 A
Efficiency
> 85%
Overcurrent
Max. 12 A
protection
Connectors
Power Connector
AC connector for power input.
2-pin terminal block for DC power output.
Install the Hardware
Note
• The AXIS T8085 is designed for use with AXIS T8646 PoE+ Over Coax Blade only.
• The length of the supplied patch cables require the AXIS T8085 to be installed immediately
below the rack with the blades.
1. Slide the AXIS T8085 into the equipment rack and fasten with the screws.
Connect the Cables
1. Connect the DC power patch cables between AXIS T8085 and up to six AXIS T8646.
Note
Use cable ties to keep the installation tidy.
2. Connect the power cord to the mains. Use the correct AC power cord for your country.
3. Verify that the blades indicate normal operation.
AXIS T8085 PS57 500W 1U
11

Publicité

loading