Thermocet Trimline 6345 Panorama Manuel D'installation page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
No ACTION
6.
Motor turns to main
gas and pilot stays lit.
OK
7.
Main burner is lit.
OK
8.
Main burner stays lit.
OK
9.
Magnet unit drops
while motor turns.
3 beeps
System can be
switched OFF via
remote control.
YES
OK
NO
Magnet unit drops
(audible click)
NO
NO
NO
NO
NO
System can be
switched OFF via
ON/OFF switch.
YES
OK
Possible problem/cause Solution
Resistance in thermo
current circuit too high.
Not enough heat on
thermocouple.
Low voltage from
thermocouple.
Short because
thermocouple end is
damaged.
IGN sequence stops. No
reaction to transmitter
command (receiver does
not react).
Gas valve manual knob in
"MAN" position.
Too much / too little air
flow / draft at pilot, blows
out or is smothered.
Receiver batteries low.
NO
Short between TC and SW
cable.
Replace gas valve.
Check cables and
connections in thermo
current circuit.
Check position of pilot to
thermocouple and intensity
of pilot flame.
Check connections and, if
necessary, replace
thermocouple. Do not over
tighten the connections!
Replace thermocouple, do
not overtighten the
connections!
Press RESET button, see
instructions.
Add ground wire between
pilot burner and gas valve.
Do not coil the IGN cable.
Shorten IGN cable if
possible.
Turn knob to "ON" position.
Check whether restriction
plate has been correctly
applied in unit, see
instructions. Poor flue
location, check correctness
of layout and connections.
Replace batteries, 1.5V AA
quality alkaline!
Check connection to
interrupter block.
Page.16