Troubleshooting; Scrapping - Advance Micromatic 13E Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH

TROUBLESHOOTING

Trouble
The motors do not turn on.
Dirty water vacuuming is insufficient or there is
no vacuuming.
The solution flow is insufficient.
The brushes do not turn.
The squeegee leaves marks on the floor.
(*)
This maintenance procedure must be performed by a Advance authorized Service Center.
For further information refer to the Service Manual, available at any Advance Service Center.

SCRAPPING

Have the machine scrapped by a qualified scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
local guidelines:
Brush
Electrical and electronic components (*)
(*)
Refer to the nearest Advance Center especially when scrapping electrical and electronic components.
18
INSTRUCTIONS FOR USE
Possible Cause
The power supply cable (10) is faulty or
disconnected from the electrical mains.
The recovery tank (16) is full.
The vacuum grid (15) is clogged.
The vacuum hose (21) is disconnected from
the deck (9) or it is damaged.
The squeegees (12 - 13) are dirty or the
squeegee blades are worn or damaged.
The gasket of the transparent cover (15) is
damaged.
The vacuum system motor is faulty.
The solution filter (25) is dirty.
The driving belt is loose or torn.
The brush motor is faulty.
There is debris under the squeegee blades
(13 - 14).
The squeegee blades (13 - 14) are worn,
chipped or torn.
9097508000(1)2008-03
Remedy
Replace the cable or connect it.
Empty.
Clean.
Connect or replace.
Clean or replace the squeegees.
Check and/or clean the seating surface or
replace the gasket.
Replace (*).
Clean.
Adjust or replace (*).
Replace (*).
Remove the debris.
Replace the blades.