a signal is received the state changes and the input becomes
active (shown under System Options > Ports & Devices).
Power Connector
2-pin terminal block for power input. Use a Safety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either a rated output
power limited to ≤100 W or a rated output current limited to ≤5 A.
Audio Connector
The Axis product has the following audio connectors:
Audio in – 3.5 mm input for a mono microphone, or a line-in
mono signal (left channel is used from a stereo signal).
Audio out – 3.5 mm output for audio (line level) that can be
connected to a public address (PA) system or an active speaker
with a built-in amplifier. A stereo connector must be used
for audio out.
RS232 Connector
5-pin terminal block for the RS232 serial interface used to control auxiliary
equipment. In order to use the RS232 port, a third party application for
AXIS Camera Application Platform is required.
RJ12 Connector
The RJ12 connector is used for connecting the sensor unit to the main unit.
For information on how to shorten the sensor unit cable see Shorten
Sensor Unit Cable.
SD card slot