MAINTENANCE
CONDENSER.
- Disconnect from the mains.
- Open the lamp house's bonnet.
- Take out the lamp.
( Refer to section 11 and proceed in reverse order).
- Turn the fast lock 1 .
- Withdraw the lens holder 2 .
- Clean the lens 3 with a soft dry cloth.
- Remount parts in reverse order.
- Clean in the same way, the 2 lenses found in the zoom.
REFLECTOR.
- Disconnect from the mains.
- Open the lamp house's bonnet.
- Take out the lamp.
( Refer to section 11 and proceed in reverse order).
- Clean the reflector 4 with a soft dry cloth.
- Remount parts in reverse order.
SPARK-GAP.
- Disconnect from the mains.
- Open the lamp house's bonnet.
- Unscrew the nut a , while holding in place the counter-nut b .
- Then, unscrew the counter-nut b .
- Adjust, with a 2,5 Allen key, the upper electrode c to
1 mm from the electrode.
- Tighten the counter-nut b and the nut a .
• The adjustment is made, when manufactured.